Opticon NFT 2100 manual Electrical Specifications Operating Voltage +5VDC + 5%

Page 9

Manual No. 25-ULNFT2100-01; Mar, 2005

NFT 2100 CCD Fixed Mount Barcode

Scanner

 

Electrical Specifications

 

 

Operating Voltage

+5VDC + 5%

 

Current

 

 

Operating (LEDs are ON)

130mA (max)

 

Idle (LEDs are OFF)

45mA (max)

 

Pwr-On Surge

1000mA (max)

 

RS232 Communications Specifications

 

RS232 Data Transmission Format

 

Parameter

Default

Optional Settings

Timing

Asynchronous

 

No. of Start Bits

1 bit

 

No. of Stop Bits

1 bit

1 or 2 bits

No of Data Bits

8 bit

7 or 8 bits

Parity

None

Odd / Even / None

Baud Rate

9600 baud

150 to 38,400 baud

Handshaking

None

Hardware / Software/ None

RS232 Transmit / Receive Character Format

Start

 

Data 7 to 8 Bits

 

(First)

 

 

 

 

 

 

 

1 Bit

LSB

 

XXXXXX

 

MSB

RS232 Transmit Data Format, Output from Scanner

Parity 1 Bit

Stop

(Last)

1 to 2 Bits

First to last

 

 

 

Global Prefix

Individual Prefix

 

Barcode data

 

 

Individual Suffix

Global Suffix

Format

 

 

 

 

0 to 8

0 to 4 characters

 

 

1 to 44

 

0 to 4 characters

 

0 to 8

 

 

 

characters

 

characters

 

characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

 

0

 

 

0

 

 

 

 

1 to 44

 

 

 

CR

0

RS232 Receive Data Format, Command inputs to scanner.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

First to last

 

 

Prefix for all

 

 

Commands

 

 

 

Suffix for all

 

 

 

 

 

 

commands

 

 

 

 

 

Commands

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Format

 

 

ESC or STX

 

1 or 2 characters

 

CR or ETX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ESC

Escape

 

 

ASCII

27

 

(x1B)

 

 

 

 

 

 

 

 

 

 

CR

Carriage Return

 

ASCII

13 (x0D)

 

 

 

 

 

 

 

 

 

 

STX

Start of Text

 

 

ASCII

2 (x02)

 

 

 

 

 

 

 

 

 

 

ETX

End of Text

 

 

ASCII

3 (x03)

 

 

 

 

RS232 Signal Level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Signal Name

In / Out

 

 

Mark/Off

Space/On

 

 

 

 

 

 

 

 

 

TXD

Out

 

 

-5 to -15

 

+5 to +15

 

 

 

 

 

 

 

 

 

RXD

In

 

 

-3 to -15

 

+3 to +15

 

 

 

Page 6

Image 9
Contents User’s Guide NFTContents Organization of this Manual Product Overview Quick Start-Up ProcedurePage Physical Specifications Symbologies SupportedOptical Specifications Skew PitchSpecified operation β at + 6º or less. Recommended at 0º Tilt Rotation 35.4RS232 Communications Specifications Electrical Specifications Operating Voltage +5VDC + 5%Environmental Specifications Connector Pin-outsOrdering Information RegulatoryAchieving Optimum Performance Distance to the Bar Code and Depth of fieldReading width or Field of View of the scanner Readable Width or Field of View for the NFT Field-of-View Specification Based Upon 69º Degree SweepAvoiding Specular Reflection Quality Bar Code LabelsMeasuring Scanner Performance Application Notes Tips for Achieving High ThroughputTips for Insuring Highest Data Integrity Tips for Verifying the Presence of a Bar Code Programming Menus & Commands Default SettingsParameter Factory Default Setting Technical Assistance and Support Common Causes of Poor PerformanceModified and/or Customized Scanners IEC 825-1 Class 1 LED Devices OpticonPage Appendix a ESC Computer Command CRWhat if you make a mistake? Reset All Defaults U2 CommandAppendix B Options for Code Direct Input Miscellaneous Characters Prefix SuffixDirect Input Alpha/Numeric Characters Direct Input Ascii Control CharactersSetting the Trigger Functions Communication DelaysSelecting the Read Mode Scanner Timeout Trigger ModeXmit Error Trigger Enabled Mode only Redundant DecodingGood Read LED Operation Delete/Deactivate Bar Code Symbologies Global Default & Scanner ConfigurationsScanner Timeout Trigger Enabled Mode only Appendix CDescription Command Symbologies Symbology SelectionComputer Function Bar Code Only MSI/PlesseyOnly EAN 13/8 +2 Symbology SelectionAdd/Activate Specific Bar Code Symbologies Add/Activate Specific Bar Code Symbologies Delete/Deactivate Bar Code SymbologiesComputer Function Command Description Disable all symbologiesDigits Add leading zero Options for UPCOptions for EAN-8 & EAN-13 7J JC JB IO IPOptions for Code 39 and IT Pharmaceutical Disable IT Pharmaceutical Options for Codabar NW-7Possible Enable normal, ABC & CX Codabar Disable ABC & Cx Codabar Page GG Enable transmit SCode as Interleaved 2 Command DescriptionF2 HF HG HJ HH HI Options for Interleaved & Industrial 2String format Meaning of Acronym Number of digits 15 total Options for IataOptions for Code-93 Options for Code-128 / EAN-128Disable length setting on all Scan Enable length setting H1 for all symbologiesI2 IL IM Creating a Prefix and/or Suffix Page UPC-E +2 or +5 Setting Prefixes Identifying the SymbologyMSI/Plessey O1 NC M9 NSetting Suffixes Identifying the Symbology O6 PC M Setting Suffixes Identifying the SymbologyDirect Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Alpha Characters Lower Case Direct Input of Control Characters ETBDEL Computer Function Bar Code Command DescriptionDirect Input Characters Misc Direct Input Characters Misc Communication Parameters Terminal Communication HandshakingQ5 LB LC LD LE Communication DelaysDisable buzzer Buzzer OperationSet buzzer at 3kHz Selecting the Read Mode Setting the Trigger FunctionsUse as Com Port Command Multiple Read Mode. will readTrigger Function Enabled S8 Trigger Function Disabled S7 ModeRead Scanner’s time out Scanner may not read the same bar YB YC YD YE Add-on Wait Mode Applies to UPC/EAN onlyZM Z1 Scanner Timeout Trigger Enabled Mode onlyBI BJ BK BL BM BN BO BH Multiple Read Reset TimeQuiet Zone Options ZO ZP ZQ ZR ZS ZT ZU ZVTransmitting Error Indications XE XDRedundant Decoding Programming No read Error Messages No read error messagesUI UJ Good Read LED OperationAppendix D Appendix E NFT 2100 Depth of Field ChartAppendix F Appendix G