Opticon NFT 2100 Communication Delays, Buzzer Operation, Setting the Trigger Functions, Labels

Page 24

Manual No. 25-ULNFT2100-01; Mar, 2005

NFT 2100 CCD Fixed Mount Barcode

Scanner

 

 

Communication Handshaking

 

 

P1

Busy/Ready

 

 

P2

Modem

 

 

P3

ACK/NAK (1 sec timeout with error buzzer)

 

 

P4

ACK/NAK no response (100 ms timeout,

terminates with good read buzzer)

 

 

 

ZG

XON/OFF

 

 

 

Communication Delays

 

 

KA

No intercharacter delay

KB

20 ms intercharacter delay

 

 

KC

50 ms intercharacter delay

 

 

KD

100 ms intercharacter delay

 

 

 

Buzzer Operation

 

 

T0

Volume = Maximum

T1

Volume = Upper mid-range

 

 

T2

Volume = Lower mid-range

 

 

T3

Volume = Minimum

 

 

W0

Disable Buzzer

 

 

W1

Enable buzzer at 3kHz

 

 

W2

Enable buzzer at 3kHz with 2.5kHz interval

W3

Enable buzzer at 3kHz with 4kHz interval

 

 

W4

Buzzer duration 0.10 sec

 

 

W5

Buzzer duration 0.20 sec

W6

Buzzer duration 0.40 sec

 

 

W7

Buzzer duration 0.05 sec

 

 

W8

Enable buzzer

 

 

 

Setting the Trigger Functions

 

 

S7

Disable the trigger function (LED On)

S8

Enable the trigger function (LED OFF until the

trigger is activated )

 

ZActivate the trigger; turns the LEDs ON

Y Terminate the trigger.

 

Selecting the Read Mode

 

 

S0

Single Read Mode (Trigger must be Enabled,

S8)

 

 

 

S1

Multiple Read Mode

S2

Continuous Read Mode

 

 

 

 

 

Scanner Timeout (Trigger Mode)

 

 

Y1

1 second after triggering

 

 

Y2

2 second after triggering

Y3

3 second after triggering

 

 

Y4

4 second after triggering

 

 

Y5

5 seconds after triggering

 

 

Y6

6 second after triggering

 

 

Y7

7 seconds after triggering

 

 

Y8

8 seconds after triggering

 

 

Y9

9 seconds after triggering

 

 

YL

Read time x 10

 

 

 

Scan time follows Hardware trigger active

Y0

time. Can be terminated by sending the Y

 

command

 

 

YM

Stays ON indefinitely after triggering. Must be

terminated by sending the Y commands.

 

 

 

 

 

 

EAN/UPC Add On Wait Times

 

 

XA

Add-on Wait Time - Disable

 

 

XB

Add-on Wait Time – 250 msec

 

 

XC

Add-on Wait Time – 500 msec

XD

Add-on Wait Time – 750 msec

 

 

 

 

 

S1 Multiple read reset time for same

 

labels

 

 

AH

Multiple Read Reset Time – 50 msec

 

 

AI

Multiple Read Reset Time – 100 msec

 

 

AJ

Multiple Read Reset Time – 200 msec

 

 

AK

Multiple Read Reset Time – 300 msec

 

 

AL

Multiple Read Reset Time – 400 msec

 

 

AM

Multiple Read Reset Time – 500 msec

AN

Multiple Read Reset Time – 600 msec

 

 

AG

Multiple Read Reset Time - Indefinite

 

 

 

 

 

Quiet Zone Options

 

 

YN

No margin check

 

 

Page 21

Image 24
Contents NFT User’s GuideContents Organization of this Manual Quick Start-Up Procedure Product OverviewPage Physical Specifications Symbologies SupportedOptical Specifications Skew PitchSpecified operation β at + 6º or less. Recommended at 0º 35.4 Tilt RotationElectrical Specifications Operating Voltage +5VDC + 5% RS232 Communications SpecificationsConnector Pin-outs Environmental SpecificationsOrdering Information RegulatoryAchieving Optimum Performance Distance to the Bar Code and Depth of fieldReading width or Field of View of the scanner Field-of-View Specification Based Upon 69º Degree Sweep Readable Width or Field of View for the NFTAvoiding Specular Reflection Quality Bar Code LabelsMeasuring Scanner Performance Application Notes Tips for Achieving High ThroughputTips for Insuring Highest Data Integrity Tips for Verifying the Presence of a Bar Code Programming Menus & Commands Default SettingsParameter Factory Default Setting Technical Assistance and Support Common Causes of Poor PerformanceModified and/or Customized Scanners Opticon IEC 825-1 Class 1 LED DevicesPage ESC Computer Command CR Appendix aReset All Defaults U2 Command What if you make a mistake?Appendix B Options for Code Prefix Suffix Direct Input Miscellaneous CharactersDirect Input Alpha/Numeric Characters Direct Input Ascii Control CharactersCommunication Delays Setting the Trigger FunctionsSelecting the Read Mode Scanner Timeout Trigger ModeXmit Error Trigger Enabled Mode only Redundant DecodingGood Read LED Operation Global Default & Scanner Configurations Delete/Deactivate Bar Code SymbologiesScanner Timeout Trigger Enabled Mode only Appendix CDescription Command Symbology Selection SymbologiesComputer Function Bar Code Only MSI/PlesseySymbology Selection Only EAN 13/8 +2Add/Activate Specific Bar Code Symbologies Delete/Deactivate Bar Code Symbologies Add/Activate Specific Bar Code SymbologiesComputer Function Command Description Disable all symbologiesOptions for UPC Digits Add leading zero7J JC JB IO IP Options for EAN-8 & EAN-13Options for Code 39 and IT Pharmaceutical Disable IT Pharmaceutical Options for Codabar NW-7Possible Enable normal, ABC & CX Codabar Disable ABC & Cx Codabar Page Command Description GG Enable transmit SCode as Interleaved 2F2 HF HG HJ HH HI Options for Interleaved & Industrial 2Options for Iata String format Meaning of Acronym Number of digits 15 totalOptions for Code-128 / EAN-128 Options for Code-93Disable length setting on all Scan Enable length setting H1 for all symbologiesI2 IL IM Creating a Prefix and/or Suffix Page Setting Prefixes Identifying the Symbology UPC-E +2 or +5O1 NC M9 N MSI/PlesseySetting Suffixes Identifying the Symbology Setting Suffixes Identifying the Symbology O6 PC MDirect Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Alpha Characters Lower Case ETB Direct Input of Control CharactersComputer Function Bar Code Command Description DELDirect Input Characters Misc Direct Input Characters Misc Communication Parameters Communication Handshaking TerminalCommunication Delays Q5 LB LC LD LEDisable buzzer Buzzer OperationSet buzzer at 3kHz Setting the Trigger Functions Selecting the Read ModeUse as Com Port Command Multiple Read Mode. will readTrigger Function Enabled S8 Trigger Function Disabled S7 ModeRead Scanner’s time out Scanner may not read the same bar Add-on Wait Mode Applies to UPC/EAN only YB YC YD YEScanner Timeout Trigger Enabled Mode only ZM Z1Multiple Read Reset Time BI BJ BK BL BM BN BO BHZO ZP ZQ ZR ZS ZT ZU ZV Quiet Zone OptionsTransmitting Error Indications XE XDRedundant Decoding No read error messages Programming No read Error MessagesUI UJ Good Read LED OperationAppendix D NFT 2100 Depth of Field Chart Appendix EAppendix F Appendix G