Tri-M Systems HE104 technical manual Output Power Connector

Page 10

23 June 2005

HE104MAN-V8 Manual

2.3.2 Output Power Connector

Output power is available for non-PC/104 use via connector CN2.

-Terminal 1: +5VDC output

-Terminal 2: Common

-Terminal 3: +12VDC

-Terminal 4: -12VDC output (optional)

-Terminal 5: -5VDC output (optional)

2.3.3Battery Power Connector (Optional)

Batteries are connected to the screw terminal block, CN3. The HE104 accepts DC battery voltages in the range of 6.5V to 40DVC through the Battery Power Connector. Two external signals can be connected to the battery terminal block for use by add-on modules plugged into the mezzanine header connectors. Connect to the HE104 Battery Terminal Block as follows:

-Terminal 1: Common of battery

-Terminal 2: Positive Battery Terminal

-Terminal 3: External signal 1

-Terminal 4: External signal 2

Note: When Optional Plug-IN Boost regulator (VR3) is ordered, batteries or external signals cannot be connected to CN3. See section 2.3.4

2.3.4 Onboard PC “Boost” Adaption (Optional)

An optional converter Boost pump (model NMH05XXS, XX=output voltage, + 5V, +9V, +12V, +15V) can be installed in location VR3 to provide custom output voltages. The NMH charge pumps have an isolated positive and negative output and a maximum 2-watt capacity. A minimum load of 10 percent is required for proper operation. By connecting the charge pump to other voltages, the user can create more or less supplies, as well as elevated and negative voltages (i.e.: The charge pump “0V” is not connected to the HE104 common).

-Terminal 1: Common of battery

-Terminal 2: -V output

-Terminal 3: 0V

-Terminal 4: +V output

Tri-M Engineering

Tel:

800.665.5600, 604.945.9565

9

1407 Kebet Way, Unit 100

Fax:

604.945.9566

 

Port Coquitlam, BC V3C 6L3

E-mail:

info@tri-m.com

 

Canada

Web site:

www.tri-m.com

 

Image 10
Contents HE104 TRI-MTechnical Manual PC/104 Vehicle Power Supply TRI-M EngineeringHE104MAN-V8 Manual Preface Introduction General DescriptionFeatures HE104 Dimensions 1000mil=1inSpecifications Model HE104Configuration and Installation IntroductionPower Considerations HE104 ConnectorsOutput Power Connector Bus Termination Optional Installation Onto PC104 ModulesJumper Selection 2 +5VDC Low Q/ Noise Q=quiescent Connector CN5 Pinout Connector CN6 Pinout PC/104 Bus Interrupts OptionalPower Management Controller PM104 optional Interrupt IRQ SelectionLow Input Alarm PM104 Pin Number and I/O Functions10 HE104 Efficiency and Heat Dissipation Calculation Switching Regulator, +5VDC Input power protectionTheory of Operation Switching regulator, +12VDC Charge PumpsFilter Capacitors Vp -p L1 ∙ frequencyExample RC1 RC2 RC3 RC4 RC5Appendix 1 HE104, +5V Regulator Block Diagram HE104MAN-V8 Manual Appendix 2 Advantages of Using AC Termination Appendix 3 Installation Hints for the HE104 Power Supply Appendix DescriptionConnections Programming Cable Sample Battery Charging Program Listing ‘Get battery charging voltage BattChrgTerm‘Return to program InitChkPwr NoPower ‘debug nopwr pauseBattTrickle ‘debug trickle gosub ChkPwr let D1 = BattChrgDistributed By