Tri-M Systems technical manual HE104MAN-V8 Manual

Page 3

23 June 2005

HE104MAN-V8 Manual

CHAPTER 1: INTRODUCTION

4

1.1 GENERAL DESCRIPTION

4

1.2 FEATURES

5

1.3 SPECIFICATIONS

6

2.1 INTRODUCTION

7

2.2 POWER CONSIDERATIONS

8

2.3 HE104 CONNECTORS

8

2.3.1 Main Input Power Connector

8

2.3.2 Output Power Connector

9

2.3.3 Battery Power Connector (Optional)

9

2.3.4 Onboard PC “Boost” Adaption (Optional)

9

2.4 BUS TERMINATION (OPTIONAL)

10

2.5 INSTALLATION ONTO PC104 MODULES

10

2.6 JUMPER SELECTION

10

2.6.1 LED Jumper Enable/Disable

10

2.6.2 +5VDC Low Q/ Noise (Q=quiescent)

11

2.6.3 +12VDC Low Q/ Noise

11

2.6.4 Mezzanine Expansion Headers

11

2.7 PC/104 BUS INTERRUPTS (OPTIONAL)

12

2.8 POWER MANAGEMENT CONTROLLER PM104 (OPTIONAL)

13

2.9 LOW INPUT ALARM

14

2.10 HE104 EFFICIENCY AND HEAT DISSIPATION CALCULATION

15

CHAPTER 3: THEORY OF OPERATION

16

3.1 INPUT POWER PROTECTION

16

3.2 SWITCHING REGULATOR, +5VDC

16

3.3 SWITCHING REGULATOR, +12VDC

17

3.4 CHARGE PUMPS

17

3.5 FILTER CAPACITORS

18

3.6 BUS TERMINATION (OPTIONAL)

19

APPENDIX 1: HE104, +5V REGULATOR BLOCK DIAGRAM:

20

APPENDIX 2: ADVANTAGES OF USING AC TERMINATION:

22

APPENDIX 3: INSTALLATION HINTS FOR THE HE104 POWER SUPPLY:

23

APPENDIX 4: VEHICLES ARE AN ELECTRONICS NIGHTMARE:

23

Tri-M Engineering

Tel:

800.665.5600, 604.945.9565

2

1407 Kebet Way, Unit 100

Fax:

604.945.9566

 

Port Coquitlam, BC V3C 6L3

E-mail:

info@tri-m.com

 

Canada

Web site:

www.tri-m.com

 

Image 3
Contents HE104 TRI-MTechnical Manual TRI-M Engineering PC/104 Vehicle Power SupplyHE104MAN-V8 Manual Preface General Description IntroductionHE104 Dimensions 1000mil=1in FeaturesModel HE104 SpecificationsIntroduction Configuration and InstallationHE104 Connectors Power ConsiderationsOutput Power Connector Installation Onto PC104 Modules Bus Termination OptionalJumper Selection 2 +5VDC Low Q/ Noise Q=quiescent PC/104 Bus Interrupts Optional Connector CN5 Pinout Connector CN6 PinoutInterrupt IRQ Selection Power Management Controller PM104 optionalPM104 Pin Number and I/O Functions Low Input Alarm10 HE104 Efficiency and Heat Dissipation Calculation Input power protection Switching Regulator, +5VDCTheory of Operation Charge Pumps Switching regulator, +12VDCVp -p L1 ∙ frequency Filter CapacitorsRC1 RC2 RC3 RC4 RC5 ExampleAppendix 1 HE104, +5V Regulator Block Diagram HE104MAN-V8 Manual Appendix 2 Advantages of Using AC Termination Appendix 3 Installation Hints for the HE104 Power Supply Description AppendixConnections Programming Cable Sample Battery Charging Program Listing BattChrgTerm ‘Get battery charging voltageInit ‘Return to programBattChrg NoPower ‘debug nopwr pauseBattTrickle ‘debug trickle gosub ChkPwr let D1 = ChkPwrDistributed By