Note: that only the ESR of the output capacitor is used in the formula. It is assumed that the capacitor is purely resistive at the frequencies about 20kHz. Worst case output ripple is at highest input voltage. Ripple voltage is independent of load (for continuous mode).

Example

Vout = 5V, Vin = 28V, L1 = 55uH, frequency = 50kNz and three 330uF capacitor with 27 mohm ESR in parallel.

Vp –p =

0.009 5(1- ( 5 ))

 

28

 

 

 

5510E6 0.5 10E5

3.6Bus Termination (Optional)

AC bus termination is provided by 5 “RC” SOIC packages (3 only for 8-bit PC/104 bus HE 104s), RC1 to RC5 and discrete components C20 and C27. Each RC package contains 16 resistor/capacitor combinations of 47R and 47PF with a common bus connected to the signal ground.

 

RC1

RC2

RC3

RC4

RC5

 

 

 

 

 

 

1

GND

GND

GND

GND

GND

 

 

 

 

 

 

2

*SMEMW

IRQ10

*BACK6

SA11

SA3

 

 

 

 

 

 

3

AEN

LA22

SD9

*Refresh

BALE

 

 

 

 

 

 

4

IOCHRDY

IRQ11

DRQ6

SA12

SA4

 

 

 

 

 

 

5

SD0

LA21

*DACK7

DRQ1

IRQ3

 

 

 

 

 

 

6

SD1

LA20

SD11

SA13

SA5

 

 

 

 

 

 

7

SRDY

IRQ15

DRQ7

*DACK1

*DACK2

 

 

 

 

 

 

8

SD2

LA19

SD12

SA14

SA6

 

 

 

 

 

 

9

SD3

LA18

-----

SA15

SA7

 

 

 

 

 

 

10

GND

GND

GND

GND

GND

 

 

 

 

 

 

11

GND

GND

GND

GND

GND

 

 

 

 

 

 

12

SD7

*MEMR

SD15

*IOW

IRQ6

 

 

 

 

 

 

13

SD6

LA17

SD14

SA17

SA9

14

SD5

LA18

SD13

*IOR

IRQ5

 

 

 

 

 

 

15

SD4

IRQ12

SD10

SA16

SA8

 

 

 

 

 

 

16

DRQ2

LA23

SD8

*DACK3

IRQ4

 

 

 

 

 

 

17

SA19

*IOCS16

DRQ5

DRQ3

DA2

 

 

 

 

 

 

18

*SMEMR

*SBHE

*MEMW

IRQ7

SA1

19

SA18

*MEMCS16

*DACK5

SA10

SA0

 

 

 

 

 

 

20

GND

GND

GND

GND

GND

 

 

 

 

 

 

 

 

 

 

 

 

In addition, the following signals are terminated with discrete components.

-

TC C1 (330pF)

 

 

 

-

Reset C20 (330pF)

 

 

 

 

 

 

 

 

 

Tri-M Engineering

Tel:

800.665.5600, 604.945.9565

19

 

1407 Kebet Way, Unit 100

Fax:

604.945.9566

 

 

Port Coquitlam, BC V3C 6L3

E-mail:

info@tri-m.com

 

 

Canada

Web site:

www.tri-m.com

 

Image 20
Contents HE104 TRI-MTechnical Manual PC/104 Vehicle Power Supply TRI-M EngineeringHE104MAN-V8 Manual Preface Introduction General DescriptionFeatures HE104 Dimensions 1000mil=1inSpecifications Model HE104Configuration and Installation IntroductionPower Considerations HE104 ConnectorsOutput Power Connector Jumper Selection Installation Onto PC104 ModulesBus Termination Optional 2 +5VDC Low Q/ Noise Q=quiescent Connector CN5 Pinout Connector CN6 Pinout PC/104 Bus Interrupts OptionalPower Management Controller PM104 optional Interrupt IRQ SelectionLow Input Alarm PM104 Pin Number and I/O Functions10 HE104 Efficiency and Heat Dissipation Calculation Theory of Operation Input power protectionSwitching Regulator, +5VDC Switching regulator, +12VDC Charge PumpsFilter Capacitors Vp -p L1 ∙ frequencyExample RC1 RC2 RC3 RC4 RC5Appendix 1 HE104, +5V Regulator Block Diagram HE104MAN-V8 Manual Appendix 2 Advantages of Using AC Termination Appendix 3 Installation Hints for the HE104 Power Supply Appendix DescriptionConnections Programming Cable Sample Battery Charging Program Listing ‘Get battery charging voltage BattChrgTerm‘Return to program InitNoPower ‘debug nopwr pause BattTrickle ‘debug trickle gosub ChkPwr let D1 =ChkPwr BattChrgDistributed By