Module and Fan Installation

CPU IOM Installation

3.Firmly press the Protection SAM IOM into the chassis until the connectors completely seat.

4.Secure the retaining screws on the top and bottom of the module, being careful not to over-tighten.

CPU IOM Installation

1.Before installing the CPU IOM, an adjustment may be needed to configure the remote shutdown operation. There are two jumpers on each CPU IOM module labeled JMP1 and JMP2. These jumpers control how the remote shutdown contacts work. As installed at the factory, jumpers JMP1 and JMP2 connect pins 1-2 to pins 3-4 so that shorting either pair will reboot both CPUs. With both jumpers removed, shorting pins 1-2 will reboot the other-slot CPU; shorting pins 3-4 will reboot the same-slot CPU. For a redundant unit with two CPUs, it is recommended that both jumpers be removed so that the CPUs can be rebooted individually without disrupting system operation.

2.Visually verify that each CPU IOM physically aligns with its respective CPU installed above, slots Q and R respectfully.

3.Firmly press each CPU IOM into the chassis until the connectors completely seat.

4.Secure the retaining screws on the top and bottom of each module, being careful not to over-tighten

APM IOM Installation

The APM IOM is installed at the factory. This power module has fuses for each power source, as well as fuse holders for two spares.