Broadmore 1750 - Release 4.6 7-69
Configuration
VP Reservation
Item Comments
Connection Name Press the space bar to select Connection Name and type a descriptive
identifier (For example, test port 2).
Local Slot The Local Slot is the chassis slot.
VP The range is 0 to one less than the value set for maximum VPs (see “Max
VP/VC” on page 7-20 for valid valu es). If the Max VP/VC value is se t to
2/65536, the VP number must be set to 0; a value of 1 is invalid.
NOTE: A maximum of 40 VPs can be defined for reservation.
VC Start The default range is 32 to the value set for maximum VCs (see “Max VP/
VC” on page 7-20 for valid values). VC numbers can start at 1 if the VP
is not set to 0.
VC End The default range is 32 to the value set for maximum VCs (see “Max VP/
VC” on page 7-20 for valid values). VC numbers can start at 1 if the VP
is not set to 0.