| Configuration |
|
| Structured DS3 SAM |
|
|
|
Table | ||
|
|
|
Item | Options | Description |
Port Name |
| A descriptive field to identify the port |
|
|
|
Port Mode | This is a status field that can be toggled to offline, in which | |
| case the port will not be available to make calls and passive | |
|
| SVCs are refused. |
|
|
|
Framing | ||
| M13 | M13 multiplexing for other purposes such as Far End Alarm |
|
| Control (FEAC) Channel. |
|
| M13 is a mode that maps 28 DS1s directly into the DS3. |
|
| The DS1s do not exist independently as is the case when |
|
| M23 multiplexing is used. |
|
|
|
Clock Mode | Network | (Synchronous) |
| derives timing from the ATM Network and propagates it to | |
| Loop | the CE Service Interface. The ATM network must be |
|
| synchronized to a single source clock. User equipment |
|
| should be configured to recover timing from the Broadmore |
|
| 1750 CE service interface. |
|
| |
|
| distributes standard timing to equipment within the central |
|
| office. The Broadmore 1750 accepts BITS via either NIM |
|
| IOM. The fallback for the primary BITS clock is the other |
|
| BITS clock. The fallback for no BITS is the internal clock |
|
| of the NIM. |
|
| (Synchronous) |
|
| will derive clock from the attached SDS3 user equipment |
|
| and transmit from the CE interface at that rate. The user |
|
| equipment should be configured for Internal timing if the |
|
| Broadmore 1750 CE service interface is configured for |
|
| Synchronous loop. |
|
|
|
Loopback | Normal | Normal Mode is no loopback. Local Line Loopback sets a |
| Local | loopback to the service equipment.Remote Loopback sets a |
| Remote | loopback to the ATM network. |
|
|
|
Service RAI | Auto | Indication (RAI) configuration. Allows user configuration |
| of the | |
| makes it transparent; the other choices set the | |
|
| either 1 or 0. |
|
|
|
Broadmore 1750 - Release 4.6 |