Security Management (FIPS Mode)

Network Interfaces

Network Interfaces

Network Interface Modules (NIMs) are installed in the Broadmore ATM Multiplexer and provide an interface to the ATM network. Each NIM contains non-volatile Flash memory for storing run-time code. These chips are not physically accessible from the ATM data path and thus cannot store data that passes through the Broadmore.

Sanitation Procedures

The following table summarizes procedures for all Broadmore modules when removing them from authorized areas to open areas.

Product Release

Product Type

Sanitation Procedure

 

 

 

Release 3.8

Broadmore Unit

Power Off for 24 hours

and earlier

 

Remove Disk-on-Chip from CPU

 

 

 

 

Network Interface

Power Off for 24 hours

 

Modules

 

 

 

 

 

CPU

Power Off for 24 hours

 

 

Remove Disk-on-Chip from CPU

 

 

 

Release 4.0

Broadmore Unit

FIPS Zeroize Global/Standby

and later

 

Power Off for 24 hours

 

 

 

 

Network Interface

Power Off for 24 hours

 

Modules

 

 

 

 

 

CPU

FIPS Zeroize Standby

 

 

Power Off for 24 hours

 

 

 

Broadmore 1750 - Release 4.6