Configuration

 

 

 

 

Structured DS3 SAM

 

 

 

 

 

 

 

 

 

 

Service Alarm

Definition

 

 

 

 

 

Excessive F-bit Errors

The Excessive F-bit Errors alarm is triggered when the DS3 port receives

 

 

F-bit errors at a rate of 1 x 10-4

 

 

 

 

 

Excessive Parity Errors

The Excessive Parity Errors alarm will be triggered when the DS3 port

 

receives parity errors at a rate of 1 x 10-4

 

 

 

 

Excessive C-bit Errors

The Excessive C-bit Errors alarm will be triggered when the DS3 port

 

 

receives C-bit errors at a rate of 1 x 10-4

 

 

 

 

Excessive FEBE Errors

The Excessive FEBE (Far End Block Error) alarm is triggered when the DS3

 

 

port receives FEBEs at a rate of 1 x 10-4

 

 

 

 

Table 7-11:Structured DS3 SAM DS1 Tributary Configuration

 

 

 

 

 

Item

 

Options

 

Description

Timing Recovery

 

SRTS Timing

 

Each option specifies a method of clock recovery

Service Clocking Mode

 

Synchronous Network

 

that will be used for all recovery circuits on the

 

Synchronous Loop

 

port.

 

 

 

 

 

 

 

NOTE: SRTS is a proprietary timing

 

 

 

 

algorithm and may ONLY be used with

 

 

 

 

specific written prior permission from

 

 

 

 

Carrier Access Corporation. Additional

 

 

 

 

license fees may apply.

 

 

 

 

 

Loopback

 

Normal

 

Normal Mode is no loopback.

 

 

Remote

 

Remote Loopback sets a loopback to the service

 

 

 

 

side.

 

 

 

 

 

Broadmore 1750 - Release 4.6

7-55

Page 169
Image 169
Carrier Access 1750 user manual 11Structured DS3 SAM DS1 Tributary Configuration