Planning and Ordering Guide

Installation Planning Factors

Installation Planning Factors

The Broadmore 1750 is designed and delivered ready for installation in a standard 19" or 23" relay or EIA equipment rack. Several factors should be considered and some decisions made to ensure a smooth installation that meets all requirements. Installation factors and system specifications are shown in the following tables.

Factor

Consideration

 

 

Access

Broadmore 1750 requires the following access clearances for

Clearance

service and maintenance:

 

Front: 24"

 

Rear: 4"

 

Top: 1.75" (Broadmore 1750 units may be stacked without this

 

clearance.)

 

 

Power

DC Power: –48 VDC at 5 amperes is connected to the rear of the

Source

Broadmore chassis. A second –48 VDC source may be connected

 

for redundancy.

 

Optional AC Power Supply Tray: Converts 110/240 VAC (50-60

 

Hz) to –48 VDC. Rack mounted tray (3.5" high) installs

 

immediately below Broadmore chassis and can hold two power

 

supplies. Unit comes with one power supply and cables. A second

 

power supply with cables can be added to provide redundant DC

 

power to the Broadmore. AC and DC power connections are at the

 

rear of the unit. The DC cable is approximately 3.5 ft. long.

 

 

Broadmore 1750 - Release 4.6

2-13

Page 63
Image 63
Carrier Access 1750 user manual Installation Planning Factors, Factor Consideration