Configuration

Unstructured E3-3 SAM

Table 7-13: Unstructured E3-3 SAM Operational Configuration

Item

Options

Comments

Port Name

 

A descriptive field to identify the port

Port Mode

On-line

This is a status field that can be toggled to off-line,in which case the port will

 

Off-line

not be available to make calls and passive SVCs are refused.

 

 

 

Framing

G.751

G.751 is a European framing standard used for PDH applications.

 

G.832

G.832 is a European framing standard set by the ITU for transporting SDH

 

Unframed

elements on PDH network.

 

 

Unframed requires a 44.736 Mbps input.

 

 

 

Clock Mode

SRTS

NOTE: SRTS is a proprietary timing algorithm and may ONLY

 

Adaptive

be used with specific written prior permission from Carrier Access

 

Network

Corporation. Additional license fees may apply.

 

BITS Clock

 

 

Loop

SRTS measures the Service Clock input frequency against a network-wide

 

 

ATM synchronization clock and sends the difference signals in the AAL1

 

 

header to the destination Broadmore 1750 circuit emulation interface. The

 

 

different signals are then combined with the network-wide ATM

 

 

synchronization clock to re-create the input service clock. If more than one

 

 

ATM clock synchronization is present in the network, an alternate timing

 

 

recovery method must be selected. For this method to work, the ATM network

 

 

must be synchronized to a single network-wide clock source. User equipment

 

 

should be configured to internal clock.

 

 

Adaptive Timing maintains a pre-defined fill level in the Circuit Emulation

 

 

Re-assembly buffer to control the timing output to user equipment. This

 

 

method of timing recovery does not require a Synchronous ATM network and

 

 

is used in applications where network wide synchronization is not available.

 

 

(Synchronous) Network method of clock recovery derives timing from the

 

 

ATM Network and propagates it to the CE Service Interface. The ATM

 

 

network must be synchronized to a single source clock. User equipment should

 

 

be configured to recover timing from the Broadmore 1750 CE service

 

 

interface.

 

 

(Synchronous) Loop CE interface will derive clock from the attached E3 user

 

 

equipment and transmit from the CE interface at that rate. The user equipment

 

 

should be configured for Internal timing if the Broadmore 1750 CE service

 

 

interface is configured for Synchronous loop.

 

 

BITS- (Building Integrated Timing Supply) distributes standard timing to

 

 

equipment within the central office. The Broadmore 1750 accepts BITS via

 

 

either NIM IOM. The fallback for the primary BITS clock is the other BITS

 

 

clock. The fallback for no BITS is the internal clock of the NIM.

 

 

 

7-58

Broadmore 1750 - Release 4.6