7-20 Broadmore 1750 - Release 4.6
Configuration
General Properties

General Properties

Max VP/VC ... 7-20
Bandwidth Meter ... 7-22
Max VP/VC
The Max VP/VC option allows you to set the maximum number of Virtual Paths
(VPs) and corresponding Virtual Channels (VCs). The maximum number of VCs
allowed per VP is based on the number of VPs set. Table 7-1 shows the Max VP/
VC settings and the valid values for VP and VC numbering.
Table 7-1: Settings for Max VP/VC and Valid Values for VP/VC Numbering
*VC numbering must start at 32 if the VP number is 0.
**For the ATM DS3, CBI, and HSSI-CBI modules, the VP number must be 0; 1 is inval id.
Max VP/VC
Setting Maximum
Number of
VPs Allowed
Valid Values
for VP
Numbering
Maximum
Number of
VCs Allowed
Valid Values
for VC
Numbering*
2/65536 1 0 or 1** 65,535 1 - 65535
4/32768 4 0 - 3 32,767 1 - 32767
8/16384 8 0 - 7 16,383 1 - 16383
16/8192 16 0 - 15 8,191 1 - 8191
32/4096
(default) 32 0 - 31 4,095 1 - 4095
64/2048 64 0 - 63 2,047 1 - 2047
128/1024 128 0 - 127 1,023 1 - 1023
256/512 256 0 - 255 511 1 - 511