Configuration

General Properties

General Properties

Max VP/VC ... 7-20

Bandwidth Meter ... 7-22

Max VP/VC

The Max VP/VC option allows you to set the maximum number of Virtual Paths (VPs) and corresponding Virtual Channels (VCs). The maximum number of VCs allowed per VP is based on the number of VPs set. Table 7-1 shows the Max VP/ VC settings and the valid values for VP and VC numbering.

Table 7-1: Settings for Max VP/VC and Valid Values for VP/VC Numbering

Max VP/VC

Maximum

Valid Values

Maximum

Valid Values

Setting

Number of

for VP

Number of

for VC

 

VPs Allowed

Numbering

VCs Allowed

Numbering*

 

 

 

 

 

2/65536

1

0 or 1**

65,535

1 - 65535

 

 

 

 

 

4/32768

4

0 - 3

32,767

1 - 32767

 

 

 

 

 

8/16384

8

0 - 7

16,383

1 - 16383

 

 

 

 

 

16/8192

16

0 - 15

8,191

1 - 8191

 

 

 

 

 

32/4096

32

0 - 31

4,095

1 - 4095

(default)

 

 

 

 

 

 

 

 

 

64/2048

64

0 - 63

2,047

1 - 2047

 

 

 

 

 

128/1024

128

0 - 127

1,023

1 - 1023

 

 

 

 

 

256/512

256

0 - 255

511

1 - 511

 

 

 

 

 

*VC numbering must start at 32 if the VP number is 0.

**For the ATM DS3, CBI, and HSSI-CBI modules, the VP number must be 0; 1 is invalid.