Module and Fan Installation
NIM IOM Installation
NIM IOM Installation
1.From the chassis rear, place the NIM IOM in slot B so that it slides easily in the top and bottom card guides with the connector aligned to the midplane connector.
2.Visually verify that the NIM IOM physically aligns with the NIM installed above.
3.Firmly press the NIM IOM into the chassis until the connectors completely seat.
4.Secure the retaining screws on the top and bottom of the module, being careful not to
5.Repeat this process for the NIM IOM in slot A.
SAM IOM Installation
1.From the chassis rear, place each SAM IOM so that it slides easily in the top and bottom card guides with the connector aligned to the midplane connector for the slot matching the corresponding SAM.
2.Visually verify that the SAM IOM physically aligns with the SAM installed above.
3.Firmly press the SAM IOM into the chassis until the connectors completely seat.
4.Secure the retaining screws on the top and bottom of the module, being careful not to
5.Repeat this process for each slot with a corresponding SAM installed.
Protection SAM IOM Installation
1.From the chassis rear, place the Protection SAM IOM so that it slides easily in the top and bottom card guides with the connector aligned to the midplane connector for the slot matching the corresponding SAM in slot P.
2.Visually verify that the Protection SAM IOM physically aligns with the SAM installed above.
Broadmore 1750 - Release 4.6 |