Configuration

OC-12c/STM-4c BITS/Timing Redundancy

The recommended configuration for maximum clocking stability is:

1.Connect BITS sources to NIM I/O A and NIM I/O B.

2.Select a Primary Reference Source (A or B), and then enable the clock loss alarm menu option on each OC-12c/STM-4c.

3.Configure the DS3 SAM to BITS clock mode.

The equipment connected to the Broadmore 1750 OC-12c/STM-4c interface is configured to BITS and provides a BITS reference clock embedded in the SONET serial stream.

4.The Broadmore 1750 OC-12c/STM-4c Transmit timing option is set to recovered.

In effect, the Broadmore 1750 OC-12c/STM-4c is loop timed off of the associated SONET device. Configuring the equipment in this manner allows the DS3 SAM to fallback on a clock derived from the associated SONET equipment’s BITS, in the event of a BITS clock failure.

7-42

Broadmore 1750 - Release 4.6

Page 156
Image 156