7-60 Broadmore 1750 - Release 4.6
Configuration
Unstructured E3-3 SAM
Table 7-15: Unstructured E3-3 SAM Alarm Configuration
Follow the sequence below to set network alarms. E3 alarms are set on a port basis with
alarm definitions as shown.
Network Alarms Options Service Alar ms
Cell Starvation Ignore/Major/Minor LOS
LOF Ignore/Major/Minor LOF
AIS Ignore/Major/Minor AIS
RDI Ignore/Major/Minor RDI
Sequence Errors Ignore/Major/Minor Line Code Violation
Excessive SNP Errors Ignore/Major/Minor Excessive F-bit Errors
Excessive F-b it Errors Ignore/Major/Minor Excessive Parity Errors
Excessive Parity Errors Ignore/Major/Minor Excessive FEBE Errors
Excessiv e FEBE Errors Ignore/Major/Minor
Select System Management ↵
Select Configure ↵
Select Slot with DS3 ↵
Select Port of interest ↵
Adjust settings using the spacebar ↵
Select Alarm Configuration ↵
Select Network Alarms ↵
Select Escape and save settings as desired ↵
Press Service Alarms ↵
Repeat the procedur e to set and save Service Alarm s ↵