Configuration

OC-12c/STM-4c BITS/Timing Redundancy

OC-12c/STM-4c BITS/Timing Redundancy

Configuration of the timing options on a redundant OC-12c/STM-4c system requires correct settings on both NIMs, the DS3 port, and the NIM redundancy screen. Either of the Broadmore 1750 BITS inputs on NIM IOMs, in slots A and B, can be selected as the primary clock reference. Each BITS input has an enable/disable menu option on the coinciding OC-12c/STM-4c interface. When a condition exists that the primary reference source is not detected, the unit will switch to the other BITS input, if a signal is detected on that input. If a signal is not detected on the opposite BITS, the source clock will be derived from an alternate source propagated from the NIM to the cell bus. The source of the cell bus clock depends on the setting of the OC-12c/STM-4c transmit timing option. Two options are available, Local/BITS and Received. The Local/BITS option derives clock from the on-board internal oscillator. The received option derives clock from the received SONET stream.

1.Follow the sequence below to set the redundancy primary BITS clock to either A or B.

Select Maintenance/Diags

Select Redundancy

Select NIM

Select Primary BITS

Choose A or B

In the case of a single BITS clock, select it as the primary source (NIM A or NIM B).