Security Management (FIPS Mode)

Enabling SecurID

Setting up the first CPU

2.Using an SSH terminal emulator, log into the online CPU and ensure that the Broadmore is operating in FIPS mode (see “Help About Security” on

page 11-17). If FIPS mode is not enabled, follow the procedure in “Enabling FIPS Mode” on page 11-18to turn on FIPS mode and then reboot the Broadmore.

3.On the SecurID server, create an Agent Host for the Broadmore and a sdconf.rec file.

4.Using SFTP software, put the sdconf.rec file into the securid directory of the Broadmore’s online CPU.

5.Using the CAMMI Administration / Security menu, select SecurID and press the space bar choose Enable. Select SecurID Interface and press the space bar to choose Ethernet. (See figure below.)

6.If the step 5 was successful, the first CPU is set up correctly and you are ready to use SecureID with that CPU. If step 5 was not successful, do not proceed until the problem is fixed.

11-22

Broadmore 1750 - Release 4.6

Page 288
Image 288
Carrier Access 1750 user manual Setting up the first CPU