J-8

[11] Jumper frequency

 

 

Sensorless vector/vector with sensor (●valid, :invalid)

Title

Communi

Function

Adjustment range

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

Speed

Torque

Position

 

cation No

 

 

communication)

setting

running

control

control

control

Constant

section



0270

Jump frequency #1

0.0 [Hz]

0.01/0.01

0.0

Enabled

●/●

6.10



0271

Jump frequency band #1

0.030.0 [Hz]

0.01/0.01

0.0

Enabled

●/●

6.10



0272

Jump frequency #2

0.0 [Hz]

0.01/0.01

0.0

Enabled

●/●

6.10



0273

Jump frequency band #2

0.030.0 [Hz]

0.01/0.01

0.0

Enabled

●/●

6.10



0274

Jump frequency #3

0.0 [Hz]

0.01/0.01

0.0

Enabled

●/●

6.10



0275

Jump frequency band #3

0.030.0 [Hz]

0.01/0.01

0.0

Enabled

●/●

6.10



0276

Object of jump frequency process

0: Process amount, 1: Output frequency

1

Enabled

●/●

6.10

[12] Preset speed operation frequency (8- to 15-stage speed)

 

 

 

 

 

 

 

 

Title

Communi

Function

Adjustment range

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

Speed

Torque

Position

 

cation No

 

 

communication)

setting

running

control

control

control

Constant

section



0287

Preset-speed #8

 [Hz]

0.01/0.01

0.0

Enabled

●/●

5.14



0288

Preset-speed #9

 [Hz]

0.01/0.01

0.0

Enabled

●/●

5.14



0289

Preset-speed #10

 [Hz]

0.01/0.01

0.0

Enabled

●/●

5.14



0290

Preset-speed #11

 [Hz]

0.01/0.01

0.0

Enabled

●/●

5.14



0291

Preset-speed #12

 [Hz]

0.01/0.01

0.0

Enabled

●/●

5.14



0292

Preset-speed #13

 [Hz]

0.01/0.01

0.0

Enabled

●/●

5.14



0293

Preset-speed #14

 [Hz]

0.01/0.01

0.0

Enabled

●/●

5.14



0294

Preset-speed #15

 [Hz]

0.01/0.01

0.0

Enabled

●/●

5.14

[13] PWM carrier frequency

 

 

 

 

 

 

 

 

 

Title

Communi

Function

Adjustment range

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

Speed

Torque

Position

 

cation No

 

 

communication)

setting

running

control

control

control

Constant

section



0300

PWM carrier frequency

0.515.0(8.0, 5.0) [kHz] (*1)

0.1/0.001

See J-28

Disabled

●/●

●/●

/●

6.12

(*1)Upper

limits differ

by applicable motor capacity.

For details, refer to 6.12.

 

 

 

 

 

 

 

 

Carrier frequency is automatically limited to less than 10kHz when operation frequency is more than 130Hz.

 

 

 

 

 

 

 

[14] Tripless intensification setup (1/2)

 

 

 

 

 

 

 

 

Title

Communi

Function

Adjustment range

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

Speed

Torque

Position

 

cation No

 

 

communication)

setting

running

control

control

control

Constant

section



0301

Auto-restart

0: Disabled, 1: Enabled(at power failure),

0

Enabled

●/●

●/●

/●

6.13.1

2: Enabled(at ST ON/OFF), 3: Enabled(1+2)

 

 

 

 

 

 

 

 

 

 

 



0302

Regenerative power ride-through

0: OFF, 1: ON, 2:ON(Deceleration stop)

0

Enabled

●/●

/

/

6.13.2

 

 

control / Deceleration stop

 

 

 

 

 

 

 

 

 



0303

Retry selection

0: Disabled, 1 to 10 times

0

Enabled

●/●

●/●

/●

6.13.3



0304

Dynamic braking mode selection

0: Disabled, 1: Enabled/overload detection enabled

See J-28

Enabled

●/●

●/●

/●

6.13.4



0305

Over-voltage stall protection

0: Enabled, 1: Disabled,

0

Enabled

●/●

●/●

/●

6.13.5

2: Enabled (Forced quick deceleration)

 

 

 

 

 

 

 

 

 

 

 



0306

Base frequency voltage #1

0.0600.0 [V]

0.1/0.1

See J-28

Enabled

●/●

●/●

/●

6.13.6

(output voltage adjustment)

 

 

 

 

 

 

 

 

 

 

 

Page 210
Image 210