[Standard connection diagram for sink logic(minus common)]

200V class: 7590kW

400V class: 110 280kW

Be sure to attach DC reactor.

Dynamic braking resistor (Optional)

DC reactor (DCL)

Refer

to 6.13.4 for details

 

*2

(Optional)

 

 

 

 

Main circuit power supply

 

 

PA

PB

PC

200V class75,90kW):

 

PO

PA

 

 

3-phase 200230V-50Hz/60Hz

 

 

 

 

400V class110280kW):

 

 

 

 

3-phese 380460V-50Hz/60Hz

 

 

 

 

MCCB

 

 

MC

R/L1

 

 

 

 

 

U/T1

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S/L2

 

 

Main

circuit

 

V/T2

 

IM

 

 

 

 

 

T/L3

 

 

 

W/T3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R0

 

Control

 

 

 

F

 

Forward

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

run signal

 

 

 

 

 

*4 S0

 

circuit

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

Reverse

 

 

 

 

RUN

 

*1 (R20)

 

 

 

 

ST

 

run signal

 

MC

 

 

*3

 

 

 

 

 

 

 

Standby

Factory

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(S20)

 

 

 

 

 

RES

 

Reset

default

 

 

 

 

 

 

FLA

 

*4

 

 

 

S1

 

Preset

settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b-contact of

 

 

 

 

 

FLB

 

 

Control panel

 

 

 

speed 1

 

overload relay

 

Surge suppressor

 

 

FL

 

S2

 

Preset

 

 

ON

 

OFF

 

 

FLC

 

 

 

 

 

 

speed 2

 

 

 

 

 

 

 

 

 

 

 

 

Preset

 

 

 

 

 

 

 

 

 

 

 

S3

 

 

 

 

 

 

 

RUN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P24

 

 

 

 

 

 

 

speed 3

 

 

RUN

 

 

 

 

 

 

 

SINK

S4

 

Preset

 

 

 

 

 

 

 

 

 

Connector for

 

 

 

 

*1:Connect a power source for

 

Ry

OUT1

SOURCE

 

speed 4

 

the control circuit.

 

 

 

common serial

 

Common

 

 

 

 

 

 

 

CC

 

 

 

 

 

 

 

 

communication

 

 

 

 

*2:The inverter is shipped

with

 

 

 

 

 

 

 

 

 

 

OUT2

RS485 connector

 

 

 

 

 

the terminals PO and PA

 

 

Ry

 

 

 

Current

signal

 

 

 

for serial

 

 

II

 

shorted with a bar. Remove

 

 

 

 

 

 

 

 

 

G/E

 

communication

 

 

 

420mA

this shorting

bar and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

install a DC reactor (DCL).

 

 

FP FM AM CC

RX VI

RR PP

 

 

 

 

*3:Power output for the control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

circuit, which

is provided

 

 

 

 

 

 

 

 

 

 

Voltage signal-10+10V

only for the 400V 37kW

 

 

 

 

 

 

 

and larger models.

 

 

 

 

 

 

 

 

 

 

 

 

Digital

 

 

 

 

 

 

 

 

 

 

 

 

Single-phase

 

 

 

Frequency Ammeter

 

 

 

 

 

 

 

207.5230V-50/60Hz

 

voltmeter

meter

 

 

 

 

 

 

 

Voltage signal010V

(10VA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltmeter or ammeter

 

 

 

External potentiometer

 

*4: Connections of control power cables by voltage for the

(or voltage signal between RR and CC: 010V)

400V 37kW and larger models.

 

 

 

 

 

 

* Connection of a RUN relay for the 400V models

Single-phase 415440V-50Hz

 

Single-phase 380415V-50/60Hz

 

 

 

 

 

(R20)

 

R46

415460V-60Hz

 

 

R46

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R41

Control

 

 

 

R41

 

Control

 

 

 

 

 

(S20)

 

 

circuit

 

 

 

 

 

circuit

 

 

 

 

 

FLA

 

S0

 

 

 

 

 

S0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLB

 

R20

 

 

 

 

 

R20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Surge suppressor

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

OFF

 

FLC

 

S20

 

 

 

 

 

S20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RUN

 

 

RUN

*5: For easy maintenance and inspection, connect the control power terminals RO and SO to the primary side of the MC in the main circuit so that the control panel can be checked if only the control circuit is energized.

B-5

Page 32
Image 32
Toshiba VF-A7 instruction manual Control, *1 R20, R20 R46, R46 R41