Avoid installing the inverter in a hot, damp, or dusty place, a place subject to freezing or water splash, or a place full of metal chips.

Do not install the inverter where there are gases that corrode metal or solvents that adversely affect plastic.

Use the inverter at ambient temperatures of -10 to 40(-10 to 50for models designed for 18.5kW motors or larger).

Measuring position

Measuring position

Note) The inverter produces heat. When installing it in a cabinet, consider its ventilating condition and internal space. When an inverter for 15kW motors or smaller is installed in a cabinet, it is advisable to peel off the label on the top of the inverter. Models for 18.5kW motors or larger can be used at ambient temperatures of up to 50. (These models have no label on their top.)

Do not install the inverter in any place subject to vibration.

Note) If you intend to install it in a place subject to vibration, you should take measures to protect it from vibration. In such a case, contact your Toshiba dealer in advance.

If installing the inverter close to any of the following appliances or devices, take necessary measures to prevent them from malfunctioning.

Solenoid ... Connect a surge suppressor to the coil. Brake ... Connect a surge suppressor to the coil.

Magnetic contactor ... Connect a surge suppressor to the coil.

Fluorescent lamp ... Connect a surge suppressor to the coil. Resistor ... Move it away from the inverter.

Resistor

A-15