Toshiba VF-A7 Table of contact input terminal function settings, Acc/dec, V/f, torque limit #2

Models: VF-A7

1 250
Download 250 pages 39.4 Kb
Page 171
Image 171

■Table of contact input terminal function settings

Parameter setting

 

Positive

Negative

Function

logic

logic

 

0

1

No assignment function

2

3

F: Forward operation command

4

5

R: Reverse operation command

6

7

ST: Standby

8

9

RES: Reset

10

11

S1: Preset-speed #1

12

13

S2: Preset-speed #2

14

15

S3: Preset-speed #3

16

17

S4: Preset-speed #4

18

19

Jog run

20

21

Emergency stop

22

23

DC injection breaking

24

25

Acceleration/deceleration

switching #1(*2)

 

 

26

27

Acceleration/deceleration

switching #2(*2)

 

 

28

29

V/f switching #1(*2)

30

31

V/f switching #2(*2)

32

33

Torque limit switching #1(*2)

34

35

Torque limit switching #2(*2)

 

 

 

36

37

PID control OFF selection

38

39

Pattern group #1

40

41

Pattern group #2

42

43

Pattern group #3

 

 

 

44

45

Pattern group #4

46

47

Pattern run continuation signal

48

49

Pattern run trigger signal

50

51

Forced Jog forward operation

 

 

 

52

53

Forced Jog reverse operation

54

55

Reservation area(*3)

56

57

Reservation area(*3)

 

 

 

58

59

Reservation area(*3)

 

 

 

60

61

Reservation area(*3)

 

 

 

62

63

Reservation area(*3)

 

 

 

64

65

Reservation area(*3)

66

67

Reservation area(*3)

68

69

Reservation area(*3)

Parameter setting

 

Positive

Negative

Function

logic

logic

 

70

71

Reservation area(*3)

72

73

Reservation area(*3)

74

75

Reservation area(*3)

76

77

Reservation area(*3)

78

79

Reservation area(*3)

80

81

Reservation area(*3)

82

83

Reservation area(*3)

84

85

Reservation area(*3)

86

87

Binary data write

88

89

Up/down frequency (up) (*1)

90

91

Up/down frequency (down) (*1)

92

93

Up/down frequency (clear)

94

95

PUSH-type run command

 

 

 

96

97

PUSH-type stop command

 

 

 

98

99

Forward/reverse selection

100

101

Run/stop command

102

103

Commercial power/INV switching

104

105

Frequency reference priority

switching

 

 

106

107

VI/II terminal priority

108

109

Command terminal board priority

110

111

Parameter editing enabling

112

113

Control switching (torque,

position)

 

 

114

115

Deviation counter clear

116

117

Position control forward limit LS

118

119

Position control reverse limit LS

120

121

Light load high-speed operation

enabling

 

 

122

123

Reservation area(*3)

124

125

Preliminary excitation

126

127

System consistent sequence

(BC: Braking command)

 

 

128

129

System-supporting sequence

(B: Brake release)

 

 

130

131

System-supporting sequence

(BA: Brake answer)

 

 

132

133

System-supporting sequence

(BT: Brake test)

 

 

134

135

Reservation area(*3)

 

 

 

 

 

 

(*1): Valid when (Speed setting mode selection) is set at (Up-down frequency). The frequency setting range is between 0.0 to (Upper limit frequency).

In this case, acceleration time is (Acceleration time #2), and deceleration time is (Deceleration time #2).

(*2): To switch acceleration/deceleration pattern, V/f pattern, torque limit #1#4, give the following signals to switching functions. (in case of positive logic)

 

switching #1

switching #2

Acc/dec, V/f, torque limit #1

OFF

OFF

Acc/dec, V/f, torque limit #2

ON

OFF

Acc/dec, V/f, torque limit #3

OFF

ON

Acc/dec, V/f, torque limit #4

ON

ON

(*3): Reservation area. Do not set at these functions. ■Sink logic/source logic

Switching between sink logic and source logic (input/output terminal logic) is possible. For details, refer to the section 2.3.2.

G-4

Page 171
Image 171
Toshiba VF-A7 instruction manual Table of contact input terminal function settings, Acc/dec, V/f, torque limit #2