11. Specifications by types

11. 1 Standard specifications by types

1) Standard specifications by types (small/medium capacity types)

 

 

Item

 

 

 

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

Voltage class

 

 

 

 

 

 

 

 

 

 

200 V class

 

 

 

 

 

 

 

 

 

 

 

Applicable motor [kW]

0.4

 

0.75

1.5

2.2

 

 

3.7

5.5

 

7.5

11

15

 

18.5

 

22

 

30

37

45

 

55

 

 

Model No.

 

 

 

 

 

 

 

 

 

 

 

VFA7–

 

 

 

 

 

 

 

 

 

 

 

 

 

Ratings

Type

2004PL

2007PL

2015PL

2022PL

2037PL

2055PL

2075PL

2110P

2150P

 

2185P

 

2220P

 

2300P

2370P1

2450P1

2550P1

 

 

Output capacity [kVA] (*1)

1.0

 

2.0

3.0

4.0

 

 

6.5

9.5

 

13

19

25

 

28

 

34

 

46

55

69

 

84

 

 

Output current [A]

3.0

 

5.0

8.0

10.5

 

 

16.6

25

 

33

49

66

 

73

 

88

 

120

144

180

 

220

 

 

Output voltage

3-phase 200 to 230 V (Maximum output voltage corresponds to input supply voltage.)

 

 

Rated overload current

 

 

 

 

150% for 2 minutes, 215% for 0.5 second (*6)

 

 

 

 

 

braking

Dynamic braking circuit

 

 

 

Built-in dynamic braking drive circuit

 

 

 

 

 

 

Optional

 

 

 

 

 

 

Built-in braking resistor

External braking resistor/ braking unit is optionally available.

 

Electric

Dynamic braking

Rating : 120W-70Ω

Rating :

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Allowable working rate: 3 % ED

working rate: 3 % ED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

resistor

 

 

 

 

 

 

120W-40Ω

 

 

 

Rating: Refer to 6.13.4.

 

 

 

 

 

 

Maximum braking: 150 %,

Maximum braking:

 

 

 

 

 

 

 

 

 

 

 

100 %, Allowable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply

 

 

Main

3-phase 200-230 V, 50/60 Hz

 

3-phase 200-220 V, 50 Hz

 

 

Voltage,

 

circuit

 

3-phase 200-230 V, 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

frequency

 

Control

 

 

 

 

 

 

 

 

Option

 

 

 

 

 

 

 

 

Single phase 200-220 V, 50 Hz

 

 

 

circuit(*2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single phase 200-230 V, 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Allowable

fluctuation

 

 

 

 

Voltage: +10% / -15% (*5), Frequency: +/-5%

 

 

 

 

 

Protection structure

 

 

 

Enclosed type (JEM1030) IP20 (*3)

 

 

 

 

 

Open type (JEMA1030) IP00 (*4)

 

Cooling system

Natural air cooling

 

 

 

 

 

 

 

Forced-air cooling

 

 

 

 

 

 

 

 

 

Coating color

 

 

 

 

 

 

 

 

 

 

Munsell 5Y-8/0.5

 

 

 

 

 

 

 

 

 

 

 

EMI filter

 

 

 

 

 

Built-in

 

 

 

 

 

Option to be installed externally

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

 

 

 

 

 

 

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

Voltage class

 

 

 

 

 

 

 

 

 

 

400 V class

 

 

 

 

 

 

 

 

 

 

 

Applicable motor [kW]

0.75

 

1.5

2.2

3.7

 

 

5.5

7.5

 

11

15

18.5

 

22

 

30

 

37

45

55

 

75

 

 

Model No.

 

 

 

 

 

 

 

 

 

 

 

VFA7–

 

 

 

 

 

 

 

 

 

 

 

 

 

Ratings

Type

4007PL

4015PL

4022PL

4037PL

4055PL

4075PL

4110PL

4150PL

4185P

 

4220P

 

4300P

4370P1

4450P1

4550P1

4750P1

 

 

Output capacity [kVA] (*1)

2.0

 

3.0

4.0

6.5

 

 

9.5

13

 

19

25

28

 

34

 

46

 

55

69

84

 

110

 

 

Output current [A]

2.5

 

4.0

5.0

8.5

 

 

13

17

 

25

33

37

 

44

 

60

 

72

90

110

 

144

 

 

Output voltage

3-phase 380 to 400 V (Maximum output voltage corresponds to input supply voltage.)

 

 

Rated overload current

 

 

 

 

150 % for 2 minutes, 215 % for 0.5 second (*6)

 

 

 

 

 

braking

Dynamic braking circuit

 

 

Built-in dynamic braking drive circuit

 

 

 

 

 

 

 

Optional

 

 

 

Dynamic braking

Built-in braking resistor

 

External braking resistor/ braking

unit is optionally available.

 

 

Electric

Rating : 120W-70Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

resistor

 

Maximum braking:

Maximum braking:

 

 

 

 

Rating: Refer to 6.13.4.

 

 

 

 

 

 

 

 

 

150 %, Allowable

100 %, Allowable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply

 

 

Main

 

 

 

3-phase 380-460 V, 50/60 Hz

 

 

 

 

3-phase 380-440 V, 50 Hz

 

Voltage,

 

circuit

 

 

 

 

 

 

 

3-phase 380-460 V, 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

frequency

 

Control

 

 

 

 

 

 

 

Option

 

 

 

 

 

 

 

Single phase 380-440 V, 50 Hz

 

 

 

circuit(*2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single phase 380-460 V, 60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Allowable

fluctuation

 

 

 

 

Voltage: +10%/-15% (*5), Frequency:

+/-5%

 

 

 

 

 

Protection structure

 

Enclosed type (JEM1030) IP20 (*3)

 

 

 

 

 

Open type (JEMA1030) IP00 (*4)

 

Cooling system

 

 

 

 

 

 

 

 

 

Forced-air cooling

 

 

 

 

 

 

 

 

 

 

 

Coating color

 

 

 

 

 

 

 

 

 

 

Munsell 5Y-8/0.5

 

 

 

 

 

 

 

 

 

 

 

EMI filter

 

 

 

 

 

Built-in

 

 

 

 

Option to be installed externally

(*1):

Rated output capacity indicates a value based on the condition that output voltage is 220 V in case of the 200 V class or

 

 

440 V in case of the 400 V class.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(*2):

The models of 22 kW or lower has no control power supply terminals(R0, S0). Optional control power supply is available

 

 

for those types.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(*3):

There are three openings for wiring; namely, wiring holes for main circuit input, for main circuit output and for control

 

 

 

circuit. After wiring is complete, close the openings properly.

 

 

 

 

 

 

 

 

 

 

 

 

 

(*4):

The models of 30 kW or higher have neither cover for the wiring hole that has a big aperture nor space for bending

 

 

 

external cables inside the unit. When a protector is installed externally, use an optional cover for the wiring hole.

 

(*5):

Allowable voltage variation is +/-10 % in continuously operation (100 % load).

 

 

 

 

 

 

 

 

 

 

(*6):

This regulation is overload value from the stop state at ambient temperature state within regulation value.

 

 

 

K-1

Page 231
Image 231
Toshiba VF-A7 instruction manual Standard specifications by types