J-9

[14] Tripless intensification setup (2/2)

 

 

Sensorless vector/vector with sensor (●valid, :invalid)

Title

Communi

Function

Adjustment range

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

Speed

Torque

Position

 

cation No

 

 

 

communication)

setting

running

control

control

control

Constant

section

 

 

Base frequency voltage

0: without voltage compensation (limitless output voltage)

 

 

 

This parameter is changeable,

 

 



0307

1: with voltage compensation (limitless output voltage)

Disabled

but significant setting value is

6.13.6

(Voltage compensation)

2: without voltage compensation (limited output voltage)

 

 

 

 

 

fixed to 1 in vector control.

 

 

 

 

 

3: with voltage compensation (limited output voltage)

 

 

 

 

 



0308

Dynamic braking resistance

1.01000 [Ω]

 

0.1/0.1

See J-28

Disabled

●/●

●/●

/●

6.13.4



0309

Dynamic braking resistor capacity

0.01600.0 [kW]

 

0.01/0.01

See J-28

Disabled

●/●

●/●

/●

6.13.4



0310

Ride-through time / Deceleration time

0.0320.0 [s]

 

0.1/0.01

2.0

Enabled

●/●

/

/

6.13.2



0311

Reverse-run prohibition

0: Permitted, 1: Reverse run prohibited,2: Forward run prohibited,

0

Disabled

●/●

●/●

6.13.7

3: Direction designated by command permitted

 

 

 

 

 

 

 

 

 

 

 



0312

Auto-restart adjustment #1

0.502.50

 

0.01/0.01

See J-28

Enabled

●/●

●/●

/

6.13.1



0313

Auto-restart adjustment #2

0.502.50

 

0.01/0.01

See J-28

Enabled

●/●

/

/

6.13.1



0314

Auto-restart mode

04

 

1/1

See J-28

Disabled

●/

●/

/

6.13.1



0315

Auto-restart adjustment #3

09

 

1/1

1

Disabled

●/

●/

/

6.13.1

[15]

Drooping

control

 

 

 

 

 

 

 

 

 

 

Title

Communi

Function

Adjustment range

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

Speed

Torque

Position

 

cation No

 

 

 

communication)

setting

running

control

control

control

Constant

section



0320

Drooping gain

0100 [%] (Enabled if = 7, 8 or 9)

1/0.01

0

Enabled

●/●

6.14



0321

Speed at drooping gain 0%

0.0320.0 [Hz] (Enabled if = 7, 8 or 9)

0.01/0.01

60.0

Enabled

●/●

6.14



0322

Speed at drooping gain 

0.0320.0 [Hz] (Enabled if = 7, 8 or 9)

0.01/0.01

60.0

Enabled

●/●

6.14



0323

Drooping insensitive torque band

0100 [%] (Enabled if = 7, 8 or 9)

1/0.1

10

Enabled

●/●

6.14



0324

Output filter for drooping

0.1200.0 [rad/s] (Enabled if = 7, 8 or 9)

0.1/0.1

100.0

Enabled

●/●

6.14



0325

Load inertia (Acc/Dec torque)

01000

 

0.1/0.1

1.0

Enabled

●/●



0326

Load torque filter (Acc/Dec torque)

0.0199.9, 200.0:without filter

0.1/0.1

200.0

Enabled

●/●

 

 

 

0: Standard, 1: Acc/dec torque removal

 

 

 

 

 

 

 

 



0327

Drooping reference selection

2: Internal torque standard

 

0

Enabled

●/●

 

 

 

3: Acc/dec torque removal (internal torque standard)

 

 

 

 

 

 

 

 

[16]

Functions

for lift (1/2)

 

 

 

 

 

 

 

 

 

 

Title

Communi

Function

Adjustment range

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

Speed

Torque

Position

 

cation No

 

 

 

communication)

setting

running

control

control

control

Constant

section



0330

Light-load high-speed operation

010

0

Disabled

●/●



0331

Light-load high-speed operation switching lower limit frequency

30.0 [Hz]

0.01/0.01

40.0

Enabled

●/●



0332

Light-load high-speed operation load waiting time

0.010.0 [s]

0.1/0.1

1.0

Enabled

●/●



0333

Light-load high-speed operation load detection time

0.010.0 [s]

0.1/0.1

1.0

Enabled

●/●



0334

Light-load high-speed operation heavy load detection time

0.010.0 [s]

0.1/0.1

5.0

Enabled

●/●



0335

Switching load torque current during forward run

0250 [%]

1

50

Enabled

●/●



0336

Heavy load torque during acceleration in forward direction

0250 [%]

1

150

Enabled

●/●



0337

Heavy load torque during fixed speed in forward direction

0250 [%]

1

100

Enabled

●/●



0338

Switching load torque current during reverse run

0250 [%]

1

50

Enabled

●/●



0339

Heavy load torque during acceleration in reverse direction

0250 [%]

1

150

Enabled

●/●

(Reference section): Refer to the inverter's individual manual.

Page 211
Image 211
Toshiba VF-A7 instruction manual Tripless intensification setup 2/2, Control, For lift 1/2