Toshiba VF-A7 instruction manual Meter output 2/2, Control Panel parameters

Models: VF-A7

1 250
Download 250 pages 39.4 Kb
Page 221
Image 221

J-19

[31] Meter output (2/2)

 

 

 

 

Sensorless vector/vector with sensor (●valid, :invalid)

Title

Communi

Function

 

Adjustment range

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

 

Speed

Torque

Position

 

cation No

 

 

 

communication)

setting

running

control

control

control

Constant

section



0690

AM/FM output parameter for adjustment

 

 

 

 

 

 

 

 

 



0697

 

 

 

 

 

 

 

 

 

 

 

[32]

Control

panel parameters

 

 

 

 

 

 

 

 

 

 

Title

Communi

Function

 

Adjustment range

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

 

Speed

Torque

Position

cation No

 

communication)

setting

running

Constant

section

 

 

 

 

 

 

 

 

control

control

control

 

 



0700

Prohibition of parameter setting

0: Allowed1: Prohibited

0

Enabled

●/●

●/●

/●

6.29.1



0701

Current/voltage display mode

0: [%], 1: [A] or [V]

0

Enabled

●/●

●/●

/●

6.29.2



0702

Frequency free unit magnification

0.00: OFF, 0.01200.0

0.01/0.01

0.00

Enabled

●/●

●/●

/●

6.29.3



0703

Decimal place number of frequency

0: 1 [Hz], 1: 0.1 [Hz], 2: 0.01 [Hz]

1

Enabled

●/●

●/●

/●

6.29.4



0704

Decimal place number of acc/dec time

0: 1[s], 1: 0.1[s], 2: 0.01[s]

1

Enabled

●/●

●/●

/●

6.29.4



0709

Prohibition of user parameter

0: Allowed

0

Enabled

initialization at type form initialization

1: Prohibited

 

 

 

 

 

 

 

 

 

 



0710

Monitor display mode setting

029

0

Enabled

●/●

●/●

/●

8.1



0711

Status monitor #1 display mode

029

1

Enabled

●/●

●/●

/●

8.1



0712

Status monitor #2 display mode

029

2

Enabled

●/●

●/●

/●

8.1



0713

Status monitor #3 display mode

029

3

Enabled

●/●

●/●

/●

8.1



0714

Status monitor #4 display mode

029

4

Enabled

●/●

●/●

/●

8.1



0720

Selection of panel V/f1, 2, 3 or 4

1: V/f #1, 2: V/f #2, 3: V/f #3, 4: V/f #4

1

Enabled

6.29.6



0721

Panel stop pattern

0: Deceleration stop1: Coast stop

0

Disabled

●/●

●/●

/●

6.29.7



0722

Panel reset function

0: Disabled, 1: Enabled

1

Disabled

●/●

●/●

/●

6.29.8



0723

Panel torque limit

14

1

Enabled

●/●

●/●

/●

6.29.9



0724

Panel PID control OFF

0: ON, 1: OFF

0

Enabled

●/●

6.29.10



0725

Panel torque reference

0250 [%]

1/0.01

0

Enabled

●/●

6.29.11



0726

Panel synchronized torque bias

-250250 [%]

1/0.01

0

Enabled

●/●

/●

6.21.4



0727

Panel tension torque bias

-250250 [%]

1/0.01

0

Enabled

●/●

6.21.4



0728

Panel load sharing gain

0250 [%]

1/0.01

100

Enabled

●/●

6.21.4



0729

Panel over-ride multiplication gain

-100100 [%]

1/0.01

0

Enabled

●/●

6.29.13

 

 

 

0: All key operations prohibited

 

 

 

 

 

 

 

 

 

 

 

+1: Panel frequency setting enabled

 

 

 

 

 

 

 

 

 

 

 

+2: Parameter reading/writing enabled

 

 

 

 

 

 

 

 



0730

Panel operation prohibition

+4: Monitor display operation enabled

63

Disabled

●/●

●/●

/●

6.29.14

+8: Panel drive operation enabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(+16: no function)

 

 

 

 

 

 

 

 

 

 

 

+32: Emergency stop operation enabled

 

 

 

 

 

 

 

 

 

 

 

63: Default mode (all key operation enabled)

 

 

 

 

 

 

 

 

Page 221
Image 221
Toshiba VF-A7 instruction manual Meter output 2/2, Control Panel parameters