Toshiba VF-A7 instruction manual , Speed setting, Panel stop pattern

Models: VF-A7

1 250
Download 250 pages 39.4 Kb
Page 70
Image 70

3) Start and stop (forward run, reverse run, free-run stop) with

the operating panel and to set the operation frequency by external signals

Title

Function

Set value



Operation command

(operating panel)

mode selection

 

Speed setting

(VI/II)



(RR)

mode selection

 

 

(RX)



Panel stop pattern

(Coast stop)

 

 

 

[Start/stop]: Press the RUN STOP key on the

operating panel.

To switch between forward run and reverse run, use the forward/reverse run selection .

[Speed command]: By means of external signals

(1)VI: 0 to +10 Vdc (0 to +5 Vdc) II: 4 to 20 mAdc

(2)RR: Volume / 0 to +10 Vdc (0 to +5 Vdc)

(3)RX: 0 to +/-10 Vdc (0 to +/-5 Vdc)

Power

R/L1

U/T1

S/L2

V/T2

supply

T/L3

W/T3

 

 

F

 

 

R

 

Operating panel

 

 

ST

 

G/E

CC

 

CC

RX VI II RR PP

Motor

IM

The inverter is shipped with these terminals shorted.

Other speed setting

: RX2 (voltage input) (optional)*

: 12/16-bit binary input (optional)*

: Serial communication (optional)*

: Serial communication RS485

: Communication add-on(optional)*

: Up-down frequency

: Pulse input (optional)*

For the setting to be made when using an asterisked optional device as an input device, refer to the instruction manual for the input device used.

③0~±10Vdc

(0~± 5Vdc)

①0~+10Vdc

(0~+ 5Vdc)

①4~20mAdc

 

External volume control

4) Start and stop (forward run, reverse run, free-run stop) and

to set the operation frequency by means of external signals

Title

Function

Set value



Operation command

(Terminal input)

mode selection

 

Speed setting

(VI/II)



(RR)

mode selection

 

 

(RX)

[Start/stop]: Connection and disconnection of terminals F and CC/terminals R and CC.

[Speed command]: By means of external signals

(1)VI: 0 to +10Vdc (0 to +5Vdc)/II: 4 to 20mAdc

(2)RR: Volume/0 to +10 Vdc (0 to +5Vdc)

(3)RX: 0 to +/-10 Vdc (0 to +/-5Vdc)

Power

R/L1

U/T1

S/L2

V/T2

supply

T/L3

W/T3

 

 

F

 

 

R

 

Control panel

 

 

ST

 

G/E

CC

 

CC RX

VI II RR PP

Motor

IM

Forward run if ON Slowdown stop if OFF Reverse run if ON Slowdown stop if OFF Standby if ON

Free-run stop if OFF

As for the action the motor takes when both the terminals F and R are connected at the same time, you can make a selection between reverse run and a stop.

=> Refer to 6.2.2

Other speed setting

: RX2 (voltage input) (optional)*

: 12/16-bit binary input (optional)*

: Serial communication (optional)*

: Serial communication RS485

③0~±10Vdc

(0~± 5Vdc)

①0~+10Vdc

(0~+ 5Vdc)

①4~20mAdc

 

External volume control

: Communication add-on(optional)*

: Up-down frequency

: Pulse input (optional)*

For the setting to be made when using an asterisked optional device as an input device, refer to the instruction manual for the input device used.

E-9

Page 70
Image 70
Toshiba VF-A7 instruction manual , Speed setting, Panel stop pattern