Toshiba VF-A7 instruction manual Standard specifications by types large capacity types

Models: VF-A7

1 250
Download 250 pages 39.4 Kb
Page 232
Image 232

2) Standard specifications by types (large capacity types)

 

 

Item

 

Description

Voltage class

 

200 V class

Applicable motor [kW]

75

 

90

 

 

Model No.

 

 

VFA7–

Ratings

 

Type

2750P1

 

2900P1

Output capacity [kVA] (*1)

110

 

133

 

 

 

Output current [A]

288

 

350

 

Output voltage

3-phase 200 to 230 V (Maximum output

voltage corresponds to input supply voltage.)

 

Rated overload current

150% for 1 minute, 180% for 0.3 second (*5)

Electric braking

Dynamic braking

Built-in type dynamic braking drive circuit is optionally available

circuit

 

Dynamic braking

External braking resistor is available optionally

 

 

resistor

 

 

 

 

supply

 

 

 

Main

 

3-phase 200-230 V, 50/60 Hz

Voltage,

 

circuit

 

 

 

 

 

 

 

 

 

Power

frequency

 

Control

 

Single phase 200-230 V, 50/60 Hz

 

 

 

circuit

 

 

 

 

 

 

 

Allowable fluctuation

Voltage: +10%/-15% (*3), Frequency: +/-5%

Protection structure

 

Open type (JEM1030) IP00 (*2)

Cooling system

 

Forced-air cooling

Coating color

 

Munsell 5Y-8/0.5

EMI filter

 

 

Option to be installed externally

Item

Voltage class

Applicable motor [kW]

 

 

Type

Ratings

 

Form

Output capacity [kVA] (*1)

 

 

Output current [A]

 

Output voltage

 

Rated overload current

 

 

Dynamic braking

Electric braking

circuit

 

 

 

Dynamic braking

 

 

resistor

Main

supply

 

 

 

Voltage,

 

circuit

 

 

Power

frequency

 

Control

 

 

 

circuit

Allowable

fluctuation

Protection structure

Cooling method

Coating color

EMI filter

Description

 

 

400 V class

 

 

90/110

132

160

220

280

 

 

VFA7–

 

 

4110KP1

4132KP1

4160KP1

4220KP1

4280KP1

160

194

236

320

412

210

255

310

420

540

3-phase 380-460 V (Maximum output voltage corresponds to input supply voltage.)

150% for 1 minute, 180% for 0.3 second (*5)

Built-in type dynamic braking drive circuit is optionally available

External braking resistor is available optionally

3-phase 380-460 V, 50/60 Hz

Single phase 380-460 V, 50/60 Hz

Voltage: +10%/-15% (*3), Frequency: +/-5%

Open type (JEM1030) IP00 (*2)

Forced-air cooling

Munsell 5Y-8/0.5

Option to be installed externally

(*1):

Rated output capacity indicates a value based on the condition that output voltage is 220 V in case of the 200 V class or

 

440 V in case of the 400 V class.

(*2):

The models of 30 kW or higher have neither cover for the wiring hole that has a big aperture nor space for bending

 

external cables inside the unit. When a protector is installed externally, use an optional cover for the wiring hole.

(*3):

Allowable voltage variation is +/-10 % in continuously operation (100 % load)

(*4):

Be sure to attach DC reactor (option) for the models: 200V class 75kW or more and 400V class 110kW or more.

 

(Not necessary for DC input.)

(*5):

This regulation is overload value from the stop state at ambient temperature state within regulation value.

3) Comparison between small/medium capacity types and large capacity types in specifications (different points only)

 

 

Small/medium capacity type

Large capacity type

 

Item

VFA7-2004PL2150P

VFA7-2185P2550P1

VFA7-2750P1,2900P1

 

 

VFA7-4007PL4150PL

VFA7-4185P4750P1

VFA7-4110KP14280KP1

 

1. Rated overload

150 % for 2 minutes

150 % for 2 minutes

150 % for 1 minutes

 

current

215 % for 0.5 second

215 % for 0.5 second

180 % for 0.3 second

 

 

Default setting: 12 kHz

Default setting: 12 kHz

Default setting: 2.2 kHz

 

 

Adjustable between 0.5 and 15 kHz

200

V class 37,45 kW type: 8 kHz

Adjustable between 0.5 and 5 kHz

 

 

200

V class 55 kW type: 2.2 kHz

 

2. PWM carrier

 

 

 

 

400

V class 37-55 kW type: 8 kHz

 

 

frequency

 

400

V class 75 kW type: 2.2 kHz

 

 

 

Adjustable between 0.5 and 15 kHz

 

 

 

 

 

 

 

 

2550P1,4750P1:

 

 

 

 

Adjustable between 0.5 and 8 kHz

 

 

3.Acceleration/deceleration

10 seconds

 

30 seconds

60 seconds

 

time (default setting)

4750P1:60 seconds

 

 

 

 

 

 

 

 

 