Toshiba VF-A7 Preset-speed operation 15 speeds, Start/stop, Setting preset-speed frequencies

Models: VF-A7

1 250
Download 250 pages 39.4 Kb
Page 89
Image 89
Function
Preset-speed #1 to #7
Adjustment range 
Adjustment range 

5.14Preset-speed operation (15 speeds)







Function

 Preset-speed #1 to #7  Preset-speed #8 to #15

 Preset-speed #1 to #15 control mode

These parameters allow you to set up to 15 operating speeds just by switching contact signals externally. Preset-speed frequencies can be set arbitrarily between the lower limit frequency  and the upper limit frequency .

[Setting method]

1) Start/stop

Start and stop control is experienced by the control panel. (Default setting)

Title

Function

Adjustment range

Default setting

 

 

: Terminal block enabled

 

 

Operation command

: Operating panel enabled

 



: Common serial communication option

mode selection

 

 

: Serial communication RS485

 

 

 

: Communication add-on cassette option

 

Note) When speeds commands (analog signal or digital signal input) need to be switched in a

preset-speed mode, then make a selection with the speed setting mode selection parameter .=> Refer to 5.3 for details.

2) Setting preset-speed frequencies

A required number of speeds (frequencies) can be set. Setting speeds 1 to 7

Title



Setting speeds 8 to 15

TitleFunction

 Preset-speed #8 to #10

Example of preset-speed contact input signal

Default setting



Default setting



0: ON, -: OFF (If all terminals are off , a speed command other than the preset speed commands is valid.)

 

 

 

 

Terminal

 

 

 

 

 

 

Preset-speed

 

 

 

 

 

 

 

 

 

S1

10

11

12

13

14

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S1-CC

 

 

 

S2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S2-CC

 

 

 

 

 

 

 

 

 

 

 

 

 

S3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S3-CC

 

 

 

 

 

 

 

 

 

S4

S4-CC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Functions assigned to terminals (Default setting)

Terminal S1

... Input terminal selection #5 (S1)

 (S1)

Terminal S2

... Input terminal selection #6 (S2)

 (S2)

Terminal S3

... Input terminal selection #7

(S3)

 (S3)

Terminal S4

... Input terminal selection #8

(S4)

 (S4)

E-28

Page 89
Image 89