J-6

[7] Speed/torque reference gain/bias setup (1/2)

 

Sensorless vector/vector with sensor (●valid, :invalid)

Title

Communi

Function

Adjustment range

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

Speed

Torque

Position

 

cation No

 

 

communication)

setting

running

control

control

control

Constant

section

 

 

 

0: 

 

 

 

 

 

 

 

 

 

 

 

1: 

 

 

 

 

 

 

 

 



0200

Reference priority selection

2:  priority (*1)

0

Enabled

●/●

6.6.1

 

 

 

3:  priority (*2)

 

 

 

 

 

 

 

 

 

 

 

4: / switching

 

 

 

 

 

 

 

 



0201

VI/II reference point #1

0100 [%]

1/0.01

20.0

Enabled

●/●

●/●

7.3.2



0202

VI/II reference point #1 frequency

0.0 [Hz]

0.01/0.01

0. 0

Enabled

●/●

●/●

7.3.2



0203

VI/II reference point #2

0100 [%]

1/0.01

100

Enabled

●/●

●/●

7.3.2



0204

VI/II reference point #2 frequency

0.0 [Hz]

0.01/0.01

80.0

Enabled

●/●

7.3.2



0205

VI/II reference point #1 rate

-250250 [%] (For torque control, etc.)

1/0.01

0

Enabled

●/●

●/●

6.21.1



0206

VI/II reference point #2 rate

-250250 [%] (For torque control, etc.)

1/0.01

100

Enabled

●/●

●/●

6.21.1



0207

Speed setting mode selection #2

Same as  (1 to 11)

1

Enabled

●/●

6.61



0208

/switching frequency

0.1 [Hz]

0.01/0.01

1.0

Enabled

●/●

6.6.1



0209

Analog input filter

0(Disabled) to 3(Max. filter capacity)

0

Enabled

●/●

●/●

7.2.4



0210

RR reference point #1

0100 [%]

1/0.01

0

Enabled

●/●

●/●

7.3.1



0211

RR reference point #1 frequency

0.0 [Hz]

0.01/0.01

0.0

Enabled

●/●

7.3.1



0212

RR reference point #2

0100 [%]

1/0.01

100

Enabled

●/●

●/●

7.3.1



0213

RR reference point #2 frequency

0.0 [Hz]

0.01/0.01

80.0

Enabled

●/●

7.3.1



0214

RR reference point #1 rate

0250 [%] (For torque control, etc.)

1/0.01

0

Enabled

●/●

●/●

6.21.1



0215

RR reference point #2 rate

0250 [%] (For torque control, etc.)

1/0.01

100

Enabled

●/●

●/●

6.21.1



0216

RX reference point #1

-100100 [%]

1/0.01

0

Enabled

●/●

●/●

7.3.3



0217

RX reference point #1 frequency

- [Hz] (*3)

0.01/0.01

0.0

Enabled

●/●

7.3.3



0218

RX reference point #2

-100100 [%]

1/0.01

100

Enabled

●/●

●/●

7.3.3



0219

RX reference point #2 frequency

- [Hz] (*3)

0.01/0.01

80.0

Enabled

●/●

7.3.3



0220

RX reference point #1 rate

0250 [%] (For torque control, etc.)

1/0.01

0

Enabled

●/●

●/●

6.21.1



0221

RX reference point #2 rate

0250 [%] (For torque control, etc.)

1/0.01

100

Enabled

●/●

●/●

6.21.1



0222

RX2 reference point #1

-100100 [%]

1/0.01

0

Enabled

●/●

●/●



0223

RX2 reference point #1 frequency

- [Hz] (*3)

0.01/0.01

0.0

Enabled

●/●



0224

RX2 reference point #2

-100100 [%]

1/0.01

100

Enabled

●/●

●/●



0225

RX2 reference point #2 frequency

- [Hz] (*3)

0.01/0.01

80.0

Enabled

●/●



0226

RX2 reference point #1 rate

-250250 [%] (For torque control, etc.)

1/0.01

0

Enabled

●/●

●/●



0227

RX2 reference point #2 rate

-250250 [%] (For torque control, etc.)

1/0.01

100

Enabled

●/●

●/●

(*1): When setup frequency(signal set up by ) is or more, signal set up by is accepted, When setup frequency is lower than , the inverter runs under the signal of .

(*2): When setup frequency(signal set up by ) is or more, signal set up by is accepted, When setup frequency is lower than , the inverter runs under the signal of .

(*3): Adjustment range is -327.68327.67 [Hz] in case of 16-bit access.

(Reference section): Refer to the inverter's individual manual.