J-16

[27] Pattern run (2/2)

 

 

Sensorless vector/vector with sensor (●valid, :invalid)

Title

Communi

Function

Adjustment range

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

Speed

Torque

Position

 

cation No

 

 

communication)

setting

running

control

control

control

Constant

section

 

 

 

0: Operation time in second after start of operation

 

 

 

 

 

 

 

 

 

 

Preset-speed #1 operation

1: Operation time in minute after start of operation

 

 

 

 

 

 

 

 



0570

2: Operation time in second after attainment of frequency

0

Disabled

●/●

6.24

continuation mode

3: Operation time in minute after attainment of frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

4: Infinite (continued until stop command is entered)

 

 

 

 

 

 

 

 

 

 

 

5: Continue until next step command

 

 

 

 

 

 

 

 



0571

Preset-speed #2 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0572

Preset-speed #3 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0573

Preset-speed #4 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0574

Preset-speed #5 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0575

Preset-speed #6 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0576

Preset-speed #7 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0577

Preset-speed #8 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0578

Preset-speed #9 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0579

Preset-speed #10 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0580

Preset-speed #11 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0581

Preset-speed #12 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0582

Preset-speed #13 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0583

Preset-speed #14 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0584

Preset-speed #15 operation continuation mode

Ditto

0

Disabled

●/●

6.24



0585

Preset-speed #1 operation time

18000 [s] / [min]

1/1

5

Enabled

●/●

6.24

(The unit depends on )

 

 

 

 

 

 

 

 

 

 

 



0586

Preset-speed #2 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0587

Preset-speed #3 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0588

Preset-speed #4 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0589

Preset-speed #5 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0590

Preset-speed #6 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0591

Preset-speed #7 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0592

Preset-speed #8 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0593

Preset-speed #9 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0594

Preset-speed #10 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0595

Preset-speed #11 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0596

Preset-speed #12 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0597

Preset-speed #13 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0598

Preset-speed #14 operation time

Ditto

1/1

5

Enabled

●/●

6.24



0599

Preset-speed #15 operation time

Ditto

1/1

5

Enabled

●/●

6.24

Page 218
Image 218