Contents of monitor indications

 

 

 

Sensorless vector/vector with sensor●: valid,: invalid

 

Communication

Function

Communication

Monitor output

Trip holding

Meter output

Speed

Torque

Position

V/f

Reference

 

number

 

unit

selection

 

selection

control

control

control

constant

section

 

Standard monitor



 

 

(*1)

 

 

 

 

 

FE00

Trip frequency monitor

0.01 [Hz]

when tripped

when tripped

●/●

●/●

/●

 

 

Contents of status monitor indications

 

 

 

 

 

 

 

 

 

 

FE90

Pattern run group selection

at a pattern run

hold

●/●

 

 

FE91

Number of times to repeat current pattern

1

at a pattern run

hold

●/●

 

 

FE92

Number of stages for multistage pattern run

1

at a pattern run

hold

●/●

 

 

FE93

Remaining time of current pattern run

1

at a pattern run

hold

●/●

 

 

FE01

Status (rotation direction)

Fixed

hold

●/●

●/●

/●

 

 

Status monitor #1



 

 

(*1)

 

 

 

 

 

Status monitor #2



 

 

(*1)

 

 

 

 

 

Status monitor #3



 

 

(*1)

 

 

 

 

 

Status monitor #4



 

 

(*1)

 

 

 

 

 

FE06

Input terminal information

Fixed

hold

●/●

●/●

/●

 

 

FE50

Input terminal information (optional)

Fixed

hold

●/●

●/●

/●

 

 

FE51

Input terminal information (optional)

Fixed

hold

●/●

●/●

/●

8.1

 

FE07

Output terminal information

Fixed

hold

●/●

●/●

/●

 

 

 

FE52

Output terminal information (optional)

Fixed

hold

●/●

●/●

/●

 

 

FE53

Output terminal information (optional)

Fixed

hold

●/●

●/●

/●

 

 

FE48

Sink/source switching status

Fixed

not hold

●/●

●/●

/●

 

 

FE47

Type of connected option

Fixed

not hold

●/●

●/●

/●

 

 

FE54

Standard default value set last

1

Fixed

not hold

●/●

●/●

/●

 

 

FE55

Last set automatic control ()

1

Fixed

not hold

●/●

●/●

/●

 

 

FE08

CPU version

1

Fixed

not hold

●/●

●/●

/●

 

 

FE43

Flush memory version

1

Fixed

not hold

●/●

●/●

/●

 

 

FE09

Control EEPROM version

1

Fixed

not hold

●/●

●/●

/●

 

 

FE44

Main circuit EEPROM version

1

Fixed

not hold

●/●

●/●

/●

 

 

FE10

Past trip #1

Fixed

not hold

●/●

●/●

/●

 

 

FE11

Past trip #2

Fixed

not hold

●/●

●/●

/●

 

 

FE12

Past trip #3

Fixed

not hold

●/●

●/●

/●

 

 

FE13

Past trip #4

Fixed

not hold

●/●

●/●

/●

 

 

FE14

Cumulative operation time

1 hour

Fixed

not hold

●/●

●/●

/●

 

Status in a trip may not be held depending on selected function. Refer to next page.