8.Monitoring operation status

8.1 Status monitor mode

Status of the inverter can be monitored.

To monitor the inverter when it is normally running,

Press the MON key twice and the current status is indicated on the LED display.

1

2

3

4

5

Setup procedure to monitor the inverter status. (EX. Operation at 60 Hz)

Com.No.

Details of indication

Key operated

LED display

Description

 

Standard monitor

 

 

Running frequency indication (in operation)

 



(In the case monitor display mode setting

 

mode

 

 

 is set at [running frequency])

 

 

 

 

FE01

Parameter setup

MON

 

Indication of "Automatic acceleration



/deceleration()" that is the first basic

 

mode

 

 

parameter

 

 

 

 

 

Status monitor

MON

 

Indication of rotating direction

FE01

mode (rotating



(: forward, : reverse)

 

direction)

 

 

 

Frequency



Indication of frequency command value.

command

(In case of =)

Load indication



Indication of inverter output current (load

current)(In case of =)

DC voltage



Indication of inverter DC voltage (Default

setting unit: [%]) (In case of =)

Output voltage



Indication of inverter output voltage (Default

setting unit: [%]) (In case of =)

 

Input terminal

 

 

Indication of ON/OFF status of control input

 



terminals (F, R, RES, ST, S1, S2, S3, S4) in

 

information #1

FE06

 

 

bits

FE50

Input terminal



Indication of ON/OFF status of optional control

FE51

information #2

 

 

input terminals (B8,B9,B10,B11) in bits

 

Input terminal



Indication of ON/OFF status of optional control

 

information #3

 

 

input terminals (B11,B12,B13,B14) in bits

 

Output terminal



Indication of ON/OFF status of control output

FE07

information #1

 

 

terminals (OUT1,OUT2,FL) in bits

Output terminal



Indication of ON/OFF status of optional control

FE52

information #2

 

 

output terminals (R1,R2,OUT3,OUT4) in bits

FE53

Output terminal



Indication of ON/OFF status of optional control

 

information #3

output terminals (ALM0,ALM1,ALM2,ALM3) in

 

 

 

bits

 

 

 

 

FE48

Sink/source



Indication of sink or source status

 

switching status

 

 

(: source, : sink)

FE47

Type of connected



Indication of connected options

option

FE54

 last set data



Indication of  value set last

 

 

 

 

 

FE55

 last set data



Indication of  value set last

 

 

 

 

 

FE08

CPU version



Indication of version of the CPU

 

 

 

 

 

FE43

Flush memory



Indication of version of the flush memory

 

version

 

 

 

FE09

Control EEPROM



Indication of version of the control EEPROM

 

version

 

 

 

FE44

Drive EEPROM



Indication of version of the drive EEPROM

version

(Continued on the following page)