(Preset-speed #1 to #15 operation continuation mode)

= (Infinite(continued until stop command is entered))

Output frequency [Hz]



 

Setting frequency



 

 

0

[s]

 

 

F-CC

 

ON

 

OFF

 

 

(Preset-speed #1 to #15 operation continuation mode) =  (Continue until next step command)

Output frequency [Hz]

Setting frequency

0

[s]

 

Step trigger signal

ON

OFF

 

Set the input terminal selection  at  (or ): pattern run trigger signal.

Notes)

Pattern operation groups should be selected by terminal input.

When the operation command mode selection is set for panel operation, pattern group #1 is always selected.(If you need a pattern other than pattern group #1, set input terminal selection () at  to , and operate with the terminal input.)

If no signal is put out from any pattern run signal (all terminals are turned off), or after the pattern run is completed, the system returns to the normal operation mode.

When two or more pattern group numbers are entered simultaneously, the pattern group operations are performed in ascending order and automatically switched to one another. In this case, it may take about 0.06 seconds to search for each pattern.

10 milliseconds after a pattern operation group selection #1, 2, 3 or 4 is activated, turn on the operation signal (F-CC). Within 10 [ms] or less, a signal for ordinary operation may be put out.

Pattern run operation

① :select pattern group #1

② :select pattern group #2

③ :select pattern group #3

 

 

 

 

 

Pattern group #1(S1-CC)

ON

Pattern group #2(S2-CC)

 

 

Pattern group

#3(S3-CC)

ON

Pattern group

#4(S4-CC)

 

 

① ② ③ ④

ON

ON

ON

ON

④ :select pattern group #4

<Parameter setting>

=(Pattern group #1) =(Pattern group #2) =(Pattern group #3) =(Pattern group #4)

F-56

Page 147
Image 147