No.

Option name

Function, purpose.

 

 

If this unit is used to connect the inverter and a personal computer and so on with each other, data communication can

 

 

be performed between the two besides easy adjustment of parameters, saving and writing data.

 

 

 

 

 

<Outline drawings with dimensions>

 

 

 

 

 

5m

 

RS-232C

 

 

 

 

 

 

 

 

 

 

communication

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

converter cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RJ45 connector

 

 

 

 

 

 

 

 

 

 

D-Sub 9pin connector

(Model: RS20035)

More than one inverter can be controlled with a personal computer and so on if this unit is used for connection between inverters and personal computer.

Computer link:Since this unit makes it possible to connect inverters with higher-class computer, FA computer, etc., a data communication network can be constructed among multiple inverters.

Communication among inverters: For the purpose of proportional operation of multiple inverters, a frequency data communication network can be constructed among multiple inverters.

<Outline drawings with dimensions>

 

RS-485 communication

25

 

100

converter unit

16.

R2.

 

(for communication with

 

 

 

 

multiple inverters)

 

 

 

 

180

168(Mounting dimension

160

 

 

R2.

 

 

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

30

 

 

 

 

(Model: RS4001Z)

(Model: RS4002Z)

 

 

Connection cable for connecting parameter writer, extension control panel,

Communication cable

RS-232C communication units, and RS-485 communication units.

 

 

Cable types: CAB0011 (1 m), CAB0013 (3 m), CAB0015 (5 m).

Remote control panel

A frequency meter, frequency setup device, RUN/STOP (forward, reverse) switch

are built in this operation panel. (Model: CBVR-7B)

 

 

 

 

Applied control units of the AP series make various applied control possible if they

 

 

are used in combination with the inverter.

 

 

■Proportional control panel (APP-2B)

■Process control panel with built-in PI

 

 

■Ratio setup panel (APH-7B)

controller (APJ-2B)

Application control units

■Regulated power supply board (APV-2B)

■TG follower panel (APF-7B)

■Cushion starter panel (APC-2B)

■Current detection panel (APD-2B)

 

 

 

■Synchronizing control panel

■Torque control panel (APL-2B)

 

 

(APS-2B1)

■FV converter (APR-2B)

 

 

■Synchronizing transmitter (DRR-2)

■Loop controller (APU-2B)

Remote control panel (APM-2B)

 

Harmonic suppression

Higher harmonic suppressor unit improves input power-factor by suppressing

 

harmonic current.

 

converter

Power regenerator unit protects the inverter from load sprung from frequent rapid

 

Power regeneration

deceleration and negative torque.

 

converter

 

For applicable models and particulars, inquire at our office.

 

 

Option ⑩~⑮ should be used under the condition of 9600 bps or less ().

I-8

Page 196
Image 196
Toshiba VF-A7 instruction manual RS-232C Communication Converter cable