J-4

[3] Terminal function selection (2/2)

 

 

Sensorless vector/vector with sensor (●valid, :invalid)

 

Communi

 

 

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

Title

cation No

Function

Adjustment range

communication)

setting

running

Speed

Torque

Position

Constant

section

 

 

 

 

 

 

 

control

control

control

 

 



0121

Input terminal selection #11 (B10)

0135

0

Disabled

●/●

●/●

/●

7.2.1



0122

Input terminal selection #12 (B11)

0135

0

Disabled

●/●

●/●

/●

7.2.1



0123

Input terminal selection #13 (B12)

0135

0

Disabled

●/●

●/●

/●

7.2.1



0124

Input terminal selection #14 (B13)

0135

0

Disabled

●/●

●/●

/●

7.2.1



0125

Input terminal selection #15 (B14)

0135

0

Disabled

●/●

●/●

/●

7.2.1



0126

Input terminal selection #16 (B15)

0135

0

Disabled

●/●

●/●

/●

7.2.1



0130

Output terminal selection #1 (OUT1)

0119

4(LOW)

Disabled

●/●

●/●

/●

7.2.2



0131

Output terminal selection #2 (OUT2)

0119

6(RCH)

Disabled

●/●

●/●

/●

7.2.2



0132

Output terminal selection #3 (FL)

0119

10(FL)

Disabled

●/●

●/●

/●

7.2.2



0133

Output terminal selection #4 (R1)

0119

0

Disabled

●/●

●/●

/●

7.2.2



0134

Output terminal selection #5 (R2)

0119

2

Disabled

●/●

●/●

/●

7.2.2



0135

Output terminal selection #6 (OUT3)

0119

8

Disabled

●/●

●/●

/●

7.2.2



0136

Output terminal selection #7 (OUT4)

0119

14

Disabled

●/●

●/●

/●

7.2.2

[4] Terminal response time setup

 

 

 

 

 

 

 

 

 

Title

Communi

Function

Adjustment range

Min. unit (panel/

Default

Write during

Vector control

V/f

Reference

Speed

Torque

Position

 

cation No

 

 

communication)

setting

running

control

control

control

Constant

section



0140

Input terminal #1 response time(F)

2 to 200 [ms] (in steps of 2.5 [ms])

(*1)

8

Disabled

●/●

●/●

/●

7.2.3



0141

Input terminal #2 response time(R)

2 to 200 [ms] (in steps of 2.5 [ms])

(*1)

8

Disabled

●/●

●/●

/●

7.2.3



0142

Input terminal #3 response time(ST)

2 to 200 [ms] (in steps of 2.5 [ms])

(*1)

8

Disabled

●/●

●/●

/●

7.2.3



0143

Input terminal #4 response time(RES)

2 to 200 [ms] (in steps of 2.5 [ms])

(*1)

8

Disabled

●/●

●/●

/●

7.2.3



0144

Input terminal #5-#8 response time

2 to 200 [ms] (in steps of 2.5 [ms])

(*1)

8

Disabled

●/●

●/●

/●

7.2.3



0145

Input terminal #9-#16 response time

2 to 200 [ms] (in steps of 2.5 [ms])

(*1)

8

Disabled

●/●

●/●

/●

7.2.3



0150

Output terminal #1 delay time (OUT1)

 

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0151

Output terminal #2 delay time (OUT2)

 

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0152

Output terminal #3 delay time (FL)

2 to 200 [ms] (in steps of 2.5 [ms])

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0153

Output terminal #4 delay time

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0154

Output terminal #5 delay time

 

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0155

Output terminal #6 delay time

 

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0156

Output terminal #7 delay time

 

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0160

Output terminal #1 holding time (OUT1)

 

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0161

Output terminal #2 holding time (OUT2)

 

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0162

Output terminal #3 holding time (FL)

2 to 200 [ms] (in steps of 2.5 [ms])

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0163

Output terminal #4 holding time

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0164

Output terminal #5 holding time

 

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0165

Output terminal #6 holding time

 

(*1)

2

Disabled

●/●

●/●

/●

7.2.3



0166

Output terminal #7 holding time

 

(*1)

2

Disabled

●/●

●/●

/●

7.2.3

(*1) The minimum setting unit is 1 ms, but that of response time is 2.5 ms. Input the value which omitted below the decimal point of a multiple of 2.5.