J-23

 

Monitor FM/AM/pulse output function selection

 

 

 

Sensorless vector/vector with sensor●: valid,: invalid

 

 

 

 

 

 

Communication

Function

Communication

Monitor output

Trip holding

Meter output

Speed

Torque

Position

V/f

Reference

 

 

number

 

unit

selection

 

selection

control

control

control

constant

section

 

0

FD00

Running frequency

0.01 [Hz]

0

(*3)

0

●/●

●/●

/●

 

 

1

FE02

Frequency command

0.01 [Hz]

1

hold

1

●/●

 

 

2

FE03

Current

0.01 [%]

2

hold

2

●/●

●/●

/●

 

 

3

FE04

DC voltage

0.01 [%]

3

hold

3

●/●

●/●

/●

 

 

4

FE05

Output voltage

0.01 [%]

4

hold

4

●/●

●/●

/●

 

 

5

FE15

After-compensation frequency

0.01 [Hz]

5

hold

5

●/●

●/●

/●

 

 

6

FE16

Speed feedback (real-time value)

0.01 [Hz]

6

hold

6

/●

/●

/●

 

 

7

FE17

Speed feedback (1 second filter)

0.01 [Hz]

7

hold

7

/●

/●

/●

 

 

8

FE18

Torque

0.01 [%]

8

hold

8

●/●

●/●

/●

●(*2)

 

 

9

FE19

Torque reference

0.01 [%]

9

hold

9

●/●

 

 

10

FE56

Internal torque reference (*1)

0.01 [%]

10

hold

10

●/●

●/●

/●

 

 

11

FE20

Torque current

0.01 [%]

11

hold

11

●/●

●/●

/●

●(*2)

 

 

12

FE21

Exciting current

0.01 [%]

12

hold

12

●/●

●/●

/●

●(*2)

 

 

13

FE22

PID feedback value

0.01 [Hz]

13

hold

13

●/●

 

 

14

FE23

Motor overload factor (OL2 data)

0.01 [%]

14

hold

14

●/●

●/●

/●

 

 

15

FE24

Inverter overload factor (OL1 data)

0.01 [%]

15

hold

15

●/●

●/●

/●

 

 

16

FE25

PBr overload factor (PBrOL data)

0.01 [%]

16

hold

16

●/●

●/●

/●

5.4

 

17

FE28

PBr load factor (pulse duty)

0.01 [%]

17

hold

17

●/●

●/●

/●

 

 

18

FE29

Input power

0.01 [kW]

18

hold

18

●/●

●/●

/●

 

 

19

FE30

Output power

0.01 [kW]

19

hold

19

●/●

●/●

/●

 

 

20

FE31

Peak output current

0.01 [%]

20

hold

20

●/●

●/●

/●

 

 

21

FE32

Peak DC voltage

0.01 [%]

21

hold

21

●/●

●/●

/●

 

 

22

FE33

Motor counter dummy PG

1 count

22

hold

22

●/●

●/●

/●

 

 

23

FE34

Position pulse

1count

23

hold

23

/●

 

 

24

FE35

PR input

0.01 [%]

24

not hold

24

●/●

●/●

/●

 

 

25

FE36

VI/II input

0.01 [%]

25

not hold

25

●/●

●/●

/●

 

 

26

FE37

RX input

0.01 [%]

26

not hold

26

●/●

●/●

/●

 

 

27

FE38

RX2 input

0.01 [%]

27

not hold

27

●/●

●/●

/●

 

 

28

FE39

FM output

0.01 [%]

28

not hold

28

●/●

●/●

/●

 

 

29

FE40

AM output

0.01 [%]

29

not hold

29

●/●

●/●

/●

 

 

30

FE57

Fixed output for meter adjustment

0.01 [%]

hold

30

●/●

●/●

/●

 

 

31

FE64

Analog output for communication

0.01 [%]

not hold

31

●/●

●/●

/●

 

 

32

FE60

Acc/dec torque removal

0.01 [%]

not hold

32

/●

/

/●

 

(*1): When =7,8,9, ●/● under speed control.

(*2): Reference data

(*3): Trip frequency is displayed in another way.

For details, refer to section 5.4; [Terminal FM-related parameters].

For monitor indications, refer to section 8.2; [Set up values of monitor indication parameters]. Communication number 31(Analog output for communication) outputs analog data of FA51.