Toshiba VF-A7 Selection of terminal functions, Changing input terminal functions

Models: VF-A7

1 250
Download 250 pages 39.4 Kb
Page 98
Image 98

6.3 Selection of terminal functions

6.3.1 Keeping an input terminal function always active (ON)

 Always active function selection

Function

This parameter is used to select a function to be kept always active (ON) from among the input terminal functions. (One function can be selected)

■Parameter setting

TitleFunction

 Always active function selection

Adjustment range



Default setting

The selected function is kept always active regardless of the type of logic (positive or negative) in the table of function settings in 7.2.1.

6.3.2 Changing input terminal functions

 Input terminal selection #1 (F)

 Input terminal selection #2 (R)

 Input terminal selection #3 (ST)

 Input terminal selection #4 (RES)

 Input terminal selection #5 (S1) Refer to 7.2.1 for details.

 Input terminal selection #6 (S2)

 Input terminal selection #7 (S3)

 Input terminal selection #8 (S4)

  Input terminal selection #9#16

6.3.3 Signal on completion of acceleration/deceleration (OUT 2)

 Output terminal selection #2 (OUT2)

Function

If this parameter is so set, a signal is put out on completion of acceleration/deceleration. Open collector output terminal OUT1 or OUT2 (24 Vdc - max. 50 mA)

■Setting of output terminal

 

Title

 

Function

Adjustment range

Setting value

 

 

 

 

 

: Acceleration/deceleration

 

 

 

Output terminal

 

completion(a-contact)

 





or

 

selection #2 (OUT2)

 

 

 

 

: Acceleration/deceleration

 

 

 

 

 

 

 

 

 

 

completion(b-contact)

Note) OUT1 for putting out a signal, select the parameter .

 

Output frequency [Hz]

 

 

 

 

 

Reference

 

 

 

 



 

 

 

(Speed reach detection band)

 

[s]

 

 

 

 

 

 

 

 

 

 

Acc. Completed(a-contact)

 

ON

 

 

OFF

 

 

 

 

 

( Acc. Completed(b-contact)

 

ON

 

OFF)

F-7

Page 98
Image 98
Toshiba VF-A7 instruction manual Selection of terminal functions, Keeping an input terminal function always active on