[29] Special analog input

 

 

 

 

Sensorless vector/vector with sensor (●valid, :invalid)

Title

Communi

Function

 

 

Adjustment range

Min. unit (panel/

Default

 

Write during

Vector control

V/f

Reference

 

 

 

Speed

Torque

Position

 

cation No

 

 

 

 

communication)

setting

 

running

control

control

control

Constant

section



0650

Acceleration/deceleration

 

0: Invalid1: VI/II2: RR

0

 

Enabled

●/●

6.26

base frequency adjustment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



0651

Upper-limit frequency adjustment

 

0: Invalid1: VI/II2: RR

0

 

Enabled

●/●

6.26



0652

Acceleration time adjustment

 

0: Invalid1: VI/II2: RR

0

 

Enabled

●/●

6.26



0653

Deceleration time adjustment

 

0: Invalid1: VI/II2: RR

0

 

Enabled

●/●

6.26



0654

Manual torque boost adjustment

 

0: Invalid1: VI/II2: RR

0

 

Enabled

6.26

[30] Over-ride

 

 

 

 

 

 

 

 

 

 

 

 

 

Title

Communi

Function

 

 

Adjustment range

Min. unit (panel/

Default

 

Write during

Vector control

V/f

Reference

 

 

 

Speed

Torque

Position

 

cation No

 

 

 

 

communication)

setting

 

running

control

control

control

Constant

section

 

 

 

 

0: Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

1: VI (voltage input)/II (current input)

 

 

 

 

 

 

 

 

 

 

 

 

 

2: RR (volume/voltage input)

 

 

 

 

 

 

 

 

 

 

 

 

 

3: RX (voltage input)

 

 

 

 

 

 

 

 

 

 

 

Over-ride addition input

 

4: RX2 (voltage input) (optional)

 

 

 

 

 

 

 

 

 



0660

 

5: Operating panel input

0

 

Enabled

●/●

6.27

selection

 

6: Binary/BCD input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7: Common serial communication option(FA01)

 

 

 

 

 

 

 

 

 

 

 

 

 

8: Serial communication RS485(FA05)

 

 

 

 

 

 

 

 

 

 

 

 

 

9: Communication add-on cassette option(FA07)

 

 

 

 

 

 

 

 

 

 

 

 

 

10: Up-down frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

11: Pulse input #1 (optional)

 

 

 

 

 

 

 

 

 



0661

Over-ride multiplication input selection

 

0: Disabled,1: VI/II,2: RR,3: RX,4: RX2,5: 

0

 

Enabled

●/●

6.27

[31] Meter output (1/2)

 

 

 

 

 

 

 

 

 

 

 

Title

Communi

Function

 

Adjustment range

Min. unit (panel/

Default

 

Write during

Vector control

V/f

Reference

 

 

Speed

Torque

Position

 

cation No

 

 

 

 

communication)

setting

 

running

control

control

control

Constant

section



0670

AM terminal meter selection

 

032

2(output

 

Enabled

●/●

●/●

/●

5.4

 

current)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



0671

AM terminal meter adjustment

 

 

Enabled

●/●

●/●

/●

5.4



0672

Optional analog terminal #1 meter selection

032

4

 

Enabled

●/●

●/●

/●



0673

Optional analog terminal #1 meter adjustment

 

Enabled

●/●

●/●

/●



0674

Optional analog terminal #2 meter selection

032

5

 

Enabled

●/●

●/●

/●



0675

Optional analog terminal #2 meter adjustment

 

Enabled

●/●

●/●

/●



0676

FP terminal meter selection

 

032

0

 

Enabled

●/●

●/●

/●

6.28.3



0677

FP terminal meter adjustment

 

1.0043.20

0.01/0.001

3.84

 

Enabled

●/●

●/●

/●

6.28.3



0678

Optional analog terminal #1 meter offset

-10.060.0

0.1/0.1

0.0

 

Enabled

●/●

●/●

/●



0679

Optional analog terminal #2 meter offset

-10.060.0

0.1/0.1

0.0

 

Enabled

●/●

●/●

/●



0680

Optional analog terminal sign selection

03

0

 

Enabled

●/●

●/●

/●

(Reference section): Refer to the inverter's individual manual.