Toshiba VF-A7 Optional add-on cassettes, Table of optional add-on cassettes, ①Vector option unit

Models: VF-A7

1 250
Download 250 pages 39.4 Kb
Page 198
Image 198

9. 5 Optional add-on cassettes

The following add-on cassette options are prepared for the inverter VF-A7. It can be applied to after CPU version “V300”.

■Table of optional add-on cassettes

Table of optional add-on cassettes

Option name

Expansion terminal function

Vector option

unit

 

 

Expansion TB

 

option unit

Commun ication function

S20 option unit

F10M option

 

 

unit

Function, purpose

Model

This option compatible to sensor

 

 

vector control is usable for speed

VEC001Z

control and position control by the

PG feedback function.

 

This option provides extended

ETB001Z

terminal functions for use.

 

This option provides TOSLINE-

TLS001Z

S20 for use.

 

This option provides TOSLINE-

TLF001Z

F10 for use

 

Remarks (*1)

A

B

Attachment

Attachment for fitting add-on

SBP001Z

For 75(132) kW or less(*3)

cassette option to the inverter.

SBP002Z

For 90(160) kW or more(*3)

 

 

(*1):

One can use two of

Group A together with one of the Group B at a time. (Maximally 3 options)

(*2):

To use 37 kW or more models in any of conditions described below, refer to 9.7 and execute the

 

preparation before attachment.

 

 

 

i ) install the vector option unit

 

 

 

ii) install the S20 option unit or the F10M option unit and execute PG feedback control

(*3):

Inside ( ) indicates case of 400V class models.

 

 

■Functions of optional add-on cassettes

Vector option unit

Function

Description

 

Consistent with line driver output encoder (Disconnection detection function is

PG feedback

also provided)

Consistent with complementary/open-collector encoder (Pulse train speed

 

command)

 

Max. pulse freq. 60kHz(2-phase), 120kHz(single-phase), Duty: 50±10%

Power supply for encoder

5 V, 6 V, 12 V, 15 V DC, 160 mA or less

Voltage drop detection

Detection of voltage drop in PG power supply line

 

Open-collector output/sink output (30 V DC, 50 mA or less)

Standby signal output

Approximately 1 second after the main circuit power is turned on, this terminal is

connected with COM. In an error status, circuit between this terminal and COM is

 

 

open regardless of main circuit power supply.

OC pre-alarm

Open-collector output/sink output (30 V DC, 50 mA or less)

When current exceeds the limiting range, this terminal is connected with COM.

 

Alarm output (Error code 0, 1,

With occurrence of an error, the cause of trip is output in 4-bit binary system. Error

is detected according to the open/closed status of the circuit between the open-

2, 3)

collector of each terminal and COM.

 

P24 power supply

+24 V DC power supply (200 mA or less) for driving external relay, etc.

PG feedback output

Open-collector outputs of phase-A positioning pulse, phase-B positioning pulse,

phase-Z positioning pulse originating from the encoder built in the motor. (30 V DC,

 

50 mA or less)

PG line driver output

Outputs phase-A positioning pulse, phase-B positioning pulse, phase-Z positioning

pulse originating from the line drive output encoder built in the motor.

 

±10 V analog command power

Power supply for ±10 V analog voltage command. (Internal impedance: 500 Ω,

supply

for 1 kΩ resistor)

±10 V analog command input

±10 V programmable voltage command is input to this terminal.

Pulse train position control

Pulse train positioning commands for forward rotation and reverse rotation are

input to this terminal. This terminal is enabled only when it is set in the position

command input

control mode or switched for position control.

 

Encoder supply voltage check

To check encoder supply voltage.

I-10