CHARCOAL EMBERS
Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner. Fine
dust found in the bottom of the bag should not be used.
21
CHARCOAL LUMPS
Place the lumps between the logs in a realistic manner taking care not to block any of the burner ports.
VERMICULITE
Sprinkle vermiculite around the charcoal embers.
Note: Both charcoal embers and vermiculite are not to be placed on the burner.
OPTIONAL BLOWER INSTALLATION
INSTALLATION TO
BE DONE BY A
QUALIFIED IN- STALLER and must be electrically con-
nected and grounded in accord- ance with local codes. In the
FIGURE 41absense of local codes, use the cur- rent CSA C22.1 CA-
NADIAN ELECTRICAL CODE
in Canada or the ANSI/NFPA 70 NA-
TIONAL ELECTRICAL CODE in the United States
If the fireplace was not previously equipped with a blower: route a grounded
The three slots on the
blower mountingFIGURE 42 bracket allow ease of
Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the se- curing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the fire- box wall.
Attach the connectors from the black and red wires to the blower.
Attach and secure the vari- able speed switch using the nut provided. Plug the harness cord into the re- ceptacle.
FIGURE 45
FIGURE 46
adjustment when attaching the blower. For a quiet running blower, do not allow the assembly to sit on the firebox base.
Slide the vibration reducing pad (A) into the clip (C) and up against the threaded stud (B) at the other end. The blower must be able to be positioned entirely onto the pad.
Tilt the blower onto its side. Slide it past the controls and into the clip (C). Secure to the threaded stud using the lock washer and wing nut provided. Ensure that the blower does not touch the fireplace base or the firebox.
FIGURE 43 |
|
B | FIGURE 44 |
| |
A | C |
|
The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, preventing it from making con- tact with moving or hot objects.
Because the blower is thermally activated, when turned on, it will automatically start approximately 10 minutes after lighting the fireplace and will run for approximately
Drywall dust will penetrate into the blower bear- ings, causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not cov- ered by the warranty policy.