6.27 Over-ride

 Over-ride addition input selection

 Over-ride multiplication input selection

Function

These parameters are used to adjust reference frequencies by means of external

Title

Function

Adjustment range

Default setting

 

 

: Disabled

 

 

 

: VI(voltage input) / II(current input)

 

 

 

: RR(volume / voltage input)

 

 

 

: RX(voltage input)

 

 

Over-ride

: RX2(voltage input)(optional)

 



addition input

: Operating panel input

selection

: Binary/BCD input(optional)

 

[Hz]

: Common serial communication option(FA01)

 

 

 

: Serial communication RS485(FA05)

 

 

 

: Communication add-on cassette option(FA07)

 

 

 

: Up/down frequency

 

 

 

: Pulse input #1(optional)

 

 

Over-ride

: Disabled

 

 

: VI(voltage input) / II(current input)

 

 

multiplication

 



: RR(volume / voltage input)

input

: RX(voltage input)

 

selection

 

 

: RX2(voltage input)(optional)

 

 

[%]

 

 

: 

 

 

 

 

The override functions calculate output frequency by the following expression:

 [%]

Output frequency ×1)+  [Hz] 100

1) Additive over-ride

In this mode, an externally input over-ride frequency is added to reference frequency.

[Ex1: RR(reference), VI(over-ride frequency)] [Ex2: RX(reference), VI(over-ride frequency)]

Output frequency [Hz]



(

Over-ride (VI input)

010V

Over-ridden frequency

RRinput )

(reference)

Output frequency [Hz] Over-ridden frequency

Forward



 

 

Over-ride

(

RR input

 

(VI input)

(reference)

 

)

 

0

10V

 

 

 

 

 

Reverse

 

 

F-63