Toshiba VF-A7 instruction manual Selection table of separate-type options

Models: VF-A7

1 250
Download 250 pages 39.4 Kb
Page 197
Image 197

Selection table of separate-type options

Voltage

Applicable

Inverter

Input AC

DC reactor

Radio noise reduction filter

High

 

Core

motor

reactor

Simple

class

[kW]

model

(ACL)

(DCL)

attenuation

type

type

 

 

 

type

(*1)

 

 

 

 

 

 

 

Motor end

Motor

Braking resistor

surge voltage

noise

(*2, 3, 4)

suppression

reduction

 

filter

filter

0.4

VFA7-2004PL

PFL-2005S

DCL-2007

 

 

0.75

VFA7-2007PL

 

 

 

(*9)

 

 

1.5

VFA7-2015PL

PFL-2011S

DCL-2022

 

2.2

VFA7-2022PL

3.7VFA7-2037PL PFL-2018S DCL-2037

 

5.5

VFA7-2055PL

PFL-2025S DCL-2055

 

 

 

 

 

PBR3-2055

 

 

 

 

7.5

VFA7-2075PL

PFL-2050S

DCL-2110

 

 

 

 

RC9129

 

PBR3-2075

 

 

 

11

VFA7-2110P

 

NF-3050A-MJ

 

 

 

PBR3-2110

 

 

 

 

 

 

 

 

 

 

 

 

200V

15

VFA7-2150P

PFL-2100S

DCL-2220

NF-3080A-MJ

 

 

 

 

PBR3-2150

 

 

18.5

VFA7-2185P

 

 

 

 

 

 

class

 

 

 

 

 

 

22

VFA7-2220P

 

 

 

NF-3100A-MJ

 

 

 

 

PBR3-2220

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

VFA7-2300P

PFL-2150S

DCL-2370 NF-3150A-MJ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

VFA7-2370P1

RCL-M2

 

 

 

 

 

 

 

45

VFA7-2450P1

PFL-2200S DCL-2450

NF-3200A-MJ

 

PBR-222W002

 

 

 

 

 

 

 

 

 

 

 

 

55

VFA7-2550P1

PFL-2300S DCL-2550

NF-3250A-MJ

 

 

 

 

 

 

 

 

NRL-2220

 

75

VFA7-2750P1

PFL-2400S

DCL-2750

NF-3200A-MJ

 

 

RC9129

 

DGP600W-B1

 

 

NRL-2300

 

 

 

 

 

 

×2 (parallel)

(*5)

 

 

 

 

 

90

VFA7-2900P1

PFL-2600S

DCL-2900

NF-3250A-MJ

 

[DGP600W-C1]

 

 

NRL-2400

 

 

 

 

 

 

 

 

 

 

 

 

 

×2 (parallel)

 

 

 

 

 

 

 

 

 

 

0.75

VFA7-4007PL

 

DCL-2007

 

 

 

 

 

 

 

MSF-4015Z

 

 

 

1.5

VFA7-4015PL

PFL-4012S

(*7) (*9)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.2

VFA7-4022PL

DCL-2022

 

 

 

 

 

 

MSF-4037Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.7

VFA7-4037PL

 

(*7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.5

VFA7-4055PL

 

 

 

 

PBR3-4055

MSF-4075Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.5

VFA7-4075PL

PFL-4025S

DCL-4110

 

 

 

 

 

PBR3-4075

 

 

 

 

 

 

 

 

 

 

 

 

11

VFA7-4110PL

 

 

 

 

 

 

RC9129

 

PBR3-4110

MSF-4150Z

 

 

15

VFA7-4150PL

 

 

 

 

 

 

 

PBR3-4150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18.5

VFA7-4185P

PFL-4050S

DCL-4220

NF-3040C-MJ

 

 

 

 

 

MSF-4220Z

 

 

 

 

 

 

 

 

 

 

 

 

22

VFA7-4220P

 

 

 

NF-3050C-MJ

 

 

 

 

PBR3-4220

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400V

30

VFA7-4300P

 

 

 

NF-3060C-MJ

 

 

 

 

 

MSF-4370Z

 

 

 

 

 

 

 

 

 

 

 

 

 

37

VFA7-4370P1

PFL-4100S

DCL-4450

 

NF-3080C-MJ

 

 

 

 

 

 

 

 

class

 

 

 

 

 

 

 

 

 

45

VFA7-4450P1

 

 

 

NF-3100C-MJ

 

 

 

 

PBR-417W008

MSF-4550Z

 

 

 

 

 

 

 

 

 

 

 

 

 

55

VFA7-4550P1

PFL-4150S DCL-4750

NF-3150C-MJ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75

VFA7-4750P1

 

 

 

 

 

 

MSF-4750Z NRL-4155

 

90/110

VFA7-4110KP1 PFL-4300S DCL-4110K

NF-3250C-MJ

RCL-M4

 

 

 

 

 

NRL-4230

 

132

VFA7-4132KP1

 

 

 

NF-3200C-MJ

 

 

 

 

DGP600W-B2

 

 

NRL-4300

 

 

 

 

×2 (parallel)

 

 

 

 

 

 

 

 

 

PFL-4400S DCL-4160K

 

 

 

RC9129

 

[DGP600W-C2]

 

 

 

 

160

VFA7-4160KP1

 

NF-3200C-MJ

 

 

 

 

 

NRL-4350

 

 

 

 

×2 (parallel)

(*5)

 

 

 

(*6)

 

 

 

 

 

 

 

 

 

 

 

 

 

220

VFA7-4220KP1 PFL-4600S DCL-4220K

NF-3250C-MJ

 

 

 

 

DGP600W-B3

 

 

NRL-4600

 

×2 (parallel)

 

 

 

 

[DGP600W-C3]

 

 

 

280

VFA7-4280KP1 PFL-4800S DCL-4280K

NF-3250C-MJ

 

 

 

 

DGP600W-B4

 

 

NRL-4550

 

×3 (parallel)

 

 

 

 

[DGP600W-C4]

 

 

(*1): This filter needs to be wound 4 turns or more around with the input side power line. This filter can be used for the output side in the same manner. For the wire whose size is 22 mm2 or more, install at least 4 filters in series. Round type (Model: RC5078) is also available.

(*2): PBR3-□□□□ indicates braking resistor.

(*3): Model in square brackets is fitted with top cover.

(*4): To use 200 V-75 kW or more or 400 V-110 kW or more inverter with an external braking resistor (DGP600 series), installation of a dynamic braking drive circuit inside the inverter is required.

(*5): There is a case that this filter is unusable depending on the type or size of the cable to be used.

(*6): About this filter for inverter models of 90 kW or more, consult with our office

(*7): These reactors are usable for each of 200V class and 400V class.

(*8): Be sure to connect DC reactor to 200V-75kW or more or 400V-110kW or more inverter. (Not necessary for DC input.)