6.2.2 Priority selection (both F-CC,R-CC are ON)

6.2 Selection of input signals

6.2.1Changing standby signal function

 ST (standby) signal selection

Function

This parameter is used to set the function of the standby signal (ST).

1)Normal setting (Standby if ST and CC are connected (ON), gate OFF if they are disconnected (OFF) (coast stop)

2)Always ON

3)Interlocked with F/R (Forward/reverse run if F/R and CC are connected, coast stop if they are disconnected)

■Parameter setting

Title

Function

Adjustment range

Default setting



ST (standby)

: Standard, : Always ON,

signal selection

: Interlocked with F/R terminal

1) Standard

Motor speed

F-CC

ST-CC

Coast stop

 

Use this setting if a standby

 

terminal is needed

 

The inverter is shipped with

ON

terminals ST and CC shorted

OFF

with a bar. Remove the

ON

shorting bar when using

OFF

these terminals.

2) Always-ON

The inverter is always on standby regardless of the status of the terminal ST. The terminal ST can be assigned to another function. In this mode, the motor slows down from the set frequency speed to a stop in the predetermined deceleration time.

3) Interlocked with terminal F (forward)/R (reverse)

Motor speed

F-CC

 

Coast stop

 

 

 

 

ON

F-CC

 

 

OFF

 

 

ST-CC

 

OFF

 

Breaking the connection of the operation frequency terminal (F/R) causes the motor to coast

to a stop. (Free-run stop)

The inverter is shipped with terminals ST and CC shorted with a bar. Remove the shorting bar when using these terminals.

 Priority selection (both F-CC, R-CC is ON)

Function

This parameter is used to select the operation to which priority is given when F-CC and R- CC are closed simultaneously.

1) Reverse run

2) Slowdown stop

■Parameter setting

TitleFunction

 Priority selection (both F-CC, R-CC are ON)

Adjustment range

:Reverse:Stop

Default setting

F-3

Page 94
Image 94
Toshiba VF-A7 instruction manual Selection of input signals, Changing standby signal function, Standard, Always-ON