[Standard connection diagram for sink logic(minus common)]

200V class: 3055kW

 

 

 

 

 

400V class: 3075kW

 

 

 

 

 

DC reactor (DCL)

 

 

 

External braking resistor (Optional)

 

 

 

Refer to 6.13.4

for details

*2 (Optional)

 

 

 

 

 

 

Installation of a dynamic braking drive

Main circuit power supply

 

 

 

 

 

 

circuit inside the

inverter is required.

200V class3055kW):

 

 

 

 

 

 

 

 

3-phase 200220V-50Hz

 

 

 

 

 

200230V-60Hz

PO

PA

PB

PC

 

400V class3075kW):

 

 

 

 

 

3-phese 380440V-50Hz

 

 

 

 

 

380460V-60Hz

 

 

 

 

 

MCCB

R/L1

 

 

 

 

U/T1

Motor

 

 

 

 

 

 

 

 

 

S/L2

 

Main

circuit

 

V/T2

IM

 

 

T/L3

 

 

W/T3

 

 

 

 

 

 

 

 

 

 

R0

Control

 

 

 

F

Forward

 

 

*1

 

 

 

 

 

 

 

S0

circuit

 

 

 

R

Reverse

 

 

 

 

 

 

 

 

 

*4

(R20)

 

 

 

 

ST

Standby

 

 

*3

 

 

 

 

 

Factory

 

 

 

 

 

 

 

 

*1: Connect a power source for

 

(S20)

 

 

 

 

RES

Reset

default

the control circuit.

 

FLA

*4

 

 

 

S1

Preset

settings

*2: The inverter is shipped with

 

 

 

 

 

 

 

the terminals PO and PA

 

FLB

 

Control panel

 

 

speed 1

 

shorted with a bar. Remove

 

 

FL

 

S2

Preset

 

this shorting bar when

 

FLC

 

 

 

 

speed 2

 

installing a DC reactor (DCL).

 

 

 

 

 

S3

Preset

 

 

 

 

 

 

 

 

*3: Power output for the control

 

 

 

 

 

 

speed 3

 

 

P24

 

 

 

 

 

 

circuit, which is provided

 

Connector for

SINK

S4

Preset

 

only for the 400V 37kW

 

 

 

 

 

Ry

OUT1

common serial

SOURCE

speed 4

 

and larger models.

communication

 

 

 

 

 

CC

Common

 

Single-phase

 

 

 

 

 

 

 

RS485 connector

 

 

 

207.5220V-50Hz

Ry

OUT2

 

 

 

Current

signal

207.5230V-60Hz

 

 

for serial

 

 

II

 

 

 

 

 

 

(10VA)

 

G/E

communication

 

 

 

420mA

 

 

 

 

 

 

 

 

FP FM AM CC

RX VI

RR PP

 

 

 

 

+ + +

Digital Frequency Ammeter

voltmeter meter

- - -

Voltage signal-10+10V

Voltage signal010V

Voltmeter or ammeter

*4: Connections of control power cables by voltage for the

400V 37kW and larger models.

 

Single-phase 415440V-50Hz

Single-phase 380415V-50/60Hz

415460V-60Hz

 

External potentiometer

(or voltage signal between RR and CC: 010V)

R46

R41

S0

R20

Control

circuit

R46

R41

S0

R20

Control

circuit

S20

S20

B-4

Page 31
Image 31
Toshiba VF-A7 instruction manual Control Circuit