Configuration

CIP over ATM (RFC 1577)

Item

Description

 

 

ATM IP Address

Enter the IP address within the subnet. Set to all

 

zeros to disable CIP.

 

 

ATM Subnet Mask

The mask is the same for all Broadmore 1750s

 

on the network.

 

 

Server Address

The address of the server containing the LIS.

 

This may be a workstation on the ATM network

 

or ATM switch. Set to zero if you want to use

 

AAL5 PVCs for CIP instead of SVCs.

 

 

Peak Cell Rate

This controls the bandwidth allocation to RFC

 

1577 support.

 

 

Enable RIP

Normally disabled. Only set to Yes for router

 

operation as the CIP subnet server.

 

 

This configures the Broadmore 1750. Some Broadmore 1750s may need routing table additions to recognize and respond to the control station via the ATM subnetwork.

These Broadmore 1750s will be configured individually, based upon network topology. Each unit may or may not have an Ethernet connection.

In the case of no Ethernet connection, the unit routes Ethernet traffic to the ATM by default. The Ethernet gateway setting is a null field. Follow the sequence on the next page to verify that no gateway is defined. Do this for each applicable Broadmore 1750 without an Ethernet connection.

Select System Management

Select Configuration

Select System Services

Select Configure IP

Select Gateway 0.0.0.0 (correct if necessary)

Broadmore 1750 - Release 4.6

7-15

Page 129
Image 129
Carrier Access 1750 user manual ATM IP Address, ATM Subnet Mask, Server Address, Peak Cell Rate, Enable RIP