Configuration
OC-12c/STM-4c
Choose the slot (A or B) containing the
Item | Options | Comment |
Port Mode | This field is a status indicator and the items displayed are | |
| the result of configuration (or other) actions. | |
| Test Download Standby |
|
| Configuration Request |
|
| Broken |
|
|
|
|
Framing Type | SONET | SDH is for International ITU applications. SONET is for |
| SDH | US applications. |
|
|
|
Transmit Timing | Recovered | Recovered means from SONET. |
| BITS | BITS impedance matching is a hardware function; see |
|
| NIM Installation, Chapter 3. BITS is tied to the local in- |
| Local | house timing source. |
| Local is | |
|
|
|
SONET Tx | Enable | If SONET Tx is enabled, framing is enabled; if SONET |
| Disable | Tx is disabled, framing is removed (i.e., SONET Tx is all |
|
| zeroes). |
|
|
|
Loopback Mode | Normal | Normal is no loopback. |
| Terminal | Terminal is a loopback from the ATM interface to the |
| Local | user equipment. |
| Local is a loopback before NIM processing to the fiber | |
| Remote | link. Remote is a loopback from the receive fiber to the |
|
| ATM before local processing. |
|
|
|
ATM Payload | Both Scrambled | A technique used to prevent a long string of zeros. Both |
Scramble Mode | Transmit Scrambled | ends of a connection must be configured the same for |
| Receive Scrambled | operation. |
| No Scramble |
|
|
|
|
BITS Clock Alarm | Enable | Provides an alarm indication of loss of BITS clock at the |
Loss | Disable | NIM IOM when enabled. A corresponding BITS LOS |
|
| SNMP trap is generated if SNMP is configured properly. |
|
|
|
If a second