SNMP Configuration

 

 

 

Notifications

 

 

 

 

 

 

 

 

Item

 

Options

Comments

 

 

 

 

Severity

 

Critical

Reboot failure, NIM major alarm.

 

 

Major

SAM major alarm, slot failure, Uni up/down.

 

 

Minor

SAM minor alarm, NIM minor alarm.

 

 

Inform

Card insert/removed, NIM switchover, CPU

 

 

 

switchover, restore, user reboot.

 

 

 

 

 

 

 

 

 

NOTE: “Severity” is an attribute only available for Broadmore enterprise

 

traps; it is not described in the RFCs. Severity is reported as a variable with

 

the trap. To configure trap severity from a remote SNMP manager, use the

 

Broadmore enterprise MIB table “snmpTrapTypeTable”.

 

 

 

 

Broadmore 1750 - Release 4.6

12-39

Page 357
Image 357
Carrier Access 1750 user manual Broadmore enterprise MIB table snmpTrapTypeTable