Configuration

OC-12c/STM-4c BITS/Timing Redundancy

2.Follow the sequence below to set the clock mode configuration on the port of interest.

Select System Management

Select Configure

Select Slot with DS3

Select Port of interest

Select Operational Configuration

Select Clock Mode

Choose the BITS option to allow the DS3 port to derive clock from either BITS or the cell bus

3.Follow the sequence below to set the OC12 transmit timing to either recovered or local/BITS. Recovered clock derives timing from the SONET stream. Local/BITS derives timing from the onboard oscillator. Repeat this step for both OC12s.

Select System Management

Select Configuration

Select Slot with OC12

Select Transit Timing

Choose Recovered or Local/BITS

Follow the sequence below to enable an alarm for loss of BITS clock. Do this for both OC-12c/STM-4cs.

Select System Management

Select Configuration

Select Slot with OC12

Select BITS Clock Alarm Loss

Choose Enable or Disable