hussman CR3HTO-HTB operation manual Lift-up Glass Maintenance, Periodic Inspection and Maintenance

Models: CR3HTO-HTB

1 18
Download 18 pages 34.75 Kb
Page 6
Image 6
Lift-up Glass Maintenance

IGFC-CR3H-HTB-1104

dust, grease, oil, and fingerprints without the need for cleaning fluids.Alight spray of the cleaning fluids listed above will reduce the time required for cleaning. These materials have been tested and proven to clean the non glare glass without scratching or damaging theAnti- reflective coating.

Cleaning solvents - for more difficult cleaning jobs, these products are recommended for the cleaning of glass. Care must be taken where they are used. The solvents are tested for use on the outside of the glass. No solvent should be applied directly to food product and food should be protected from overspray unless they carry the USDA-A1 ranking.

The food should be covered or the solution should be sprayed on a cleaning cloth away from the case if it is to be used inside the case with product present.

The following products will not damage the non-glare coating on the glass:

Windex®

Glass-Plus®

Exceed™ Multi Surface Glass Cleaner - from Kay Chemical Company, Greensboro, NC

Warm water

Under no circumstances should the following be used for cleaning glass:

Coarse paper towels

Souring Pads or Powders

Steel wool or steel fiber materials

Blades

Acidic or highlyAlkaline detergents

Fluorine based detergents

Lift-up Glass Maintenance

At Installation and after replacement:

The top cylinders, which allow the raising and lowering of the glass, have been carefully tested for proper tension. However, during shipment, the lubricant inside may have settled. This settling may cause excessive or uneven tension on the glass - to the point of breakage.

Before opening the glass for the first time and after installing new cylinders, it is advisable to perform these three easy steps before completely raising the front glass.

1.Slowly raise and lower each glass section 6 times, to a height of 6".

2.Increase the height to 12", and raise and lower the glass 6 more times.

3.Finally, raise the glass to it's full extension. This should release any settled lubricant in the cylinders, and prevent any stress on the front glass.

After the case is brought to operating temperature the first time, recheck the Allen screws on the glass once the case once the case is in full operation and brought to temperature.

Temperature changes can affect the size and shape of the materials involved, and can cause changes in the secure fit of the glass and the clamp.

Cylinders are a wear item. They are designed:Have your Service Contractor replace the cylinders when required.CAUTION

Cylinders are a wear item. They are designed:

•To support the glass when fully open •to allow the glass to close slowly

Have your Service Contractor replace the cylinders when required.

Glass is heavy and can cause bodily damage. Check support cylinders for periodic maintenance

Periodic Inspection and Maintenance

Piston cylinders are a wear item. They are designed to support the glass when fully open and to allow the glass to close slowly. Glass is heavy and can cause bodily damage.

Check support cylinders as a part of periodic mainte- nance. Have your Service Contractor replace the cylinders if they show signs of weakness or when

6

Page 6
Image 6
hussman CR3HTO-HTB operation manual Lift-up Glass Maintenance, Periodic Inspection and Maintenance