L O C AT I O N
The merchandisers have been designed for use only in air conditioned stores where temperature and humidity are maintained at or below 75°F and 55% relative humidity. DO NOT allow air conditioning, electric fans, open doors or windows (etc.) to create air currents around the merchandiser, as this will impair its correct operation.
Product temperature should always be maintained at a constant and proper temperature. This means that from the time the product is received, through storage, preparation and display, the temperature of the product must be controlled to maximize life of the product.
Place the fixture as close to its permanent position as possible. Remove the top of the crate. Detach the walls from each other and remove from the skid. Unbolt the case from the skid. The fixture can now be lifted off the crate skid. Lift only at base of stand!
EXTERIOR LOADING
These models have not been structurally designed to support excessive external loading. Do not walk on their tops; This could cause serious personal injury and damage to the fixture.
GLASS BREAKAGE
MAY OCCUR!
Retighten glass along clamshell after leveling and first time case is brought to full operating temperature!
GLASS ADJUSTMENT
During shipment, the lubricant inside the cylinders may have settled. This settling may cause excessive or uneven tension on the glass - to the point of breakage. To avoid any damage, please follow these three easy steps:
1.Slowly raise and lower each glass section 6 times to a height of 6 inches.
2.Increase the height to 12 inches, and raise and lower the glass 6 more times.
3.Finally raise the glass to its full extension, and lower. These steps should release any settled lubricant within the cylinders and prevent any stress on the front glass.
LEVELING
IMPORTANT! It is imperative that cases and supporting counters be leveled from front to back and side to side prior to joining. A level case is necessary to insure proper operation, water drainage, and plexiglass alignment.
NOTE: A.To avoid removing concrete flooring, begin lineup leveling from the highest point of the store floor.
B. When wedges are involved in a lineup, set them first.
Installation
All cases were tested at a level state before shipping. When joining, use a carpenters level and shim enclosing or supporting cabinet accordingly.
1.Make sure the cabinet you are installing the FC4H CINNABON on is level.
2.Wire unit according to local codes.
Electrical
WIRING COLOR CODE
L1 | BLACK |
L2 | ORANGE |
L3 | BLUE |
NEUTRAL | WHITE |
|
|
NOTE: High Leg Connection
Orange Only
CASE MUST BE GROUNDED
NOTE: Refer to label affixed to case to determine the actual configuration as checked in the “TYPE INSTALLED” boxes.
ELECTRICAL CIRCUIT IDENTIFICATION
Standard lighting for all models will be full length fluorescent lamps located within the case at the top.
The switch controlling the lights, the plug provided for digital scale, and the thermometer are located at the rear of the case mullion.
The receptacle that is provided on the exterior back of these models is intended for computerized scales with a five amp maximum load, not for large motors or other high wattage appliances. It should be wired to a dedi- cated circuit.
ELECTRICAL SERVICE RECEPTACLES (When Applicable)
The receptacles located on the exterior of the merchan- diser are intended for scales and lighted displays. They
4